CPX230NWB ALARM CONTROL UNIT – USER MANUAL
7 / 42
EN
USERS
1 service code (ATS – Alarm Transmission System is a special type of user, meaning the
monitoring station, that is authorized by the main access code to the device)
1 installer code
1 admin code (main)
31 user codes
Possibility to restrict the scope of authorization to a few codes only
SYSTEM OPTIONS
Automatic diagnosis of basic system components
Possibility to review faults, alarm memories, event log
System/technical event history – min. 5000 events
2.2.
SPECIFICATIONS
Supply voltage:
18VAC (16-20VAC)
Required transformer Power:
min. 20VA max 60VA
Supported modems:
*
model CPX230NWB-5xx
: Cinterion BGS2-W
(GSM: 850, 900, 1800, 1900 MHz)
*
model CPX230NWB-6xx
: Cinterion EHS6
(UMTS: 800, 850, 900, 1900, 2100 MHz;
GSM: 850, 900, 1800, 1900 MHz)
Current consumption average/max:
(average measured: fully charged battery, established
connection with server, connected keypad, no sensors
connected)
120mA / 180mA @18VAC
* Measured with BGS2-W Cinterion
95mA / 170mA @18VAC
* Measured with EHS6 Cinterion
Average current consumption; lack of
external supply (without keypad/ with
keypad):
(fully charged battery, established connection with
server, no sensors connected)
60mA / 85mA @13VDC
* Measured with BGS2-W Cinterion
35mA / 65mA @13VDC
* Measured with EHS6 Cinterion
Charging current:
(measured with totalny discharged battrey)
max. 350mA
Charging voltage:
13.8V
Supported bartery type:
Lead-acid 12V
Low voltage – event treshold:
11V
Voltage battery cut off level:
below 9V
Working temperature:
-10ºC to +55ºC
Working humidity:
5% to 93%
PCB dimensions:
152mm x 78mm x 30mm