List of events handled by the SETUSERSMS and GETUSERSMS commands
Alias name
Description
ARM1
Partition 1 armed
ARMSTAY1
Partition 1 armed in perimeter mode
ARM2
Partition 2 armed
ARMSTAY2
Partition 2 armed in perimeter mode
DISARM1
Partition 1 disarmed
DISARM2
Partition 2 disarmed
INPUT1
(to INPUT32)
Violation of zones 1…32
INPUT1-OFF
(to INPUT32-OFF)
Violation of zones 1…32 ended
INPUT1-TAMPER
(to INPUT32-TAMPER)
Sabotage of zones 1…32
INPUT1-TAMPEREND
(to INPUT32-TAMPEREND)
Sabotage of zones 1…32 ended
INPUT1-LOCK
(to INPUT32-LOCK)
Bypass of zones 1…32
INPUT1-UNLOCK
(to INPUT32-UNLOCK)
Bypass of zones 1…32 ended
OUTPUT1-ON
(to OUTPUT3-ON)
Zones 1…3 triggered
OUTPUT1-OFF
(to OUTPUT3-OFF)
Zones 1…3 trigger ended
OUTPUT1-TAMPER
(to OUTPUT3-TAMPER)
Fault of zones 1…3
OUTPUT1-TAMPEREND
(to OUTPUT3-TAMPEREND)
Fault of zones 1…3 ended
POWER-FAIL
Power failure
POWER-OK
Power failure ended
BATTERY-FAIL
Battery failure
BATTERY-OK
Battery failure ended
AUX1-FAIL
Failure of auxiliary output 1
AUX2-FAIL
Failure of auxiliary output 2
AUX1-OK
Failure of auxiliary output 1 ended
AUX2-OK
Failure of auxiliary output 2 ended