background image

Version of the manual: v1.3 
Date of issue: 26.07.2018 

 

 

EN 

 

 

 
 

ALARM CONTROL PANEL 

CPX230NWB 

 

User manual 

Firmware version: 

 

 

2.10.0   

GPRS transmitter configurator version:  1.4.85.3 

OSM server version: 

 

 

1.3.71.036 

 

 

 

Содержание CPX230NWB

Страница 1: ...Version of the manual v1 3 Date of issue 26 07 2018 EN ALARM CONTROL PANEL CPX230NWB User manual Firmware version 2 10 0 GPRS transmitter configurator version 1 4 85 3 OSM server version 1 3 71 036...

Страница 2: ...not be deemed to be providing any warranties either express or implicit including but not limited to any implied warranties of merchantability or fitness for a particular purpose unless it is required...

Страница 3: ...KP2W KEYPAD 18 7 4 3 ARMING FROM THE REMOTE 18 7 5 QUICK ARMING WITH MODE AND PARTITION SELECTION 18 7 5 1 ARMING USING A KP32 KEYPAD 19 7 5 2 ARMING USING A KP2W KEYPAD 20 7 5 3 QUICK SWITCHING OF A...

Страница 4: ...OL UNIT USER MANUAL 4 42 EN 9 10 PROGRAMMING TIME 30 9 11 PROGRAMMING DATE 31 9 12 TESTING THE ZONES 31 9 13 TESTING THE OUTPUTS 31 9 14 DURESS CODE 32 9 15 EMERGENCY BUTTONS 32 9 16 TEXT MESSAGES 32...

Страница 5: ...ter intended for small and medium sized facilities The control panel is equipped with 3 outputs and 7 wired for TEOL configuration up to 14 and up to 32 wireless zones with the possibility to be divid...

Страница 6: ...50mA 1 keypad output max current 100mA PARTITIONS 2 partitions with the possibility to assign any number of zones to each of them KEYPAD cooperation with LED KEYPAD KP32 ability to connect up to three...

Страница 7: ...model CPX230NWB 6xx Cinterion EHS6 UMTS 800 850 900 1900 2100 MHz GSM 850 900 1800 1900 MHz Current consumption average max average measured fully charged battery established connection with server co...

Страница 8: ...x 82 x 19 mm Keypad type LED 16 status LEDs 4 mode LEDs GROUP ALARM SYSTEM PROG Button layout Standard telephone keypad 3 x 4 buttons Drawing 1 KP32 Keypad 1 FULLY ARMED mode arming symbol indicated...

Страница 9: ...red 5 Partition input or output sabotage failure symbol indicated with diodes E partition P1 and 5 partition P2 Blinks quickly no longer present but there were failures sabotage of inputs or outputs a...

Страница 10: ...on on the remote where Blinks alarm triggered in the past Lit continuously current alarm 15 SYSTEM diode When this diode is lit it means a system failure e g power failure battery failure ATS connecti...

Страница 11: ...nction button which enables switching between groups 28 Screw connectors Connectors for connecting cables leading from keypads to the alarm control 29 Cable entry hole A place for inserting connection...

Страница 12: ...in the lower right corner of the display This means that the information is send to the alarm control panel The keypad transmits the entered characters as soon as any of the following conditions is me...

Страница 13: ...transmission 3 Keypad buttons Buttons on the KP2W keypad function the same as on the KP32 keypad see section 3 KEYPAD KP32 SPECIFICATION points 17 to 27 After first pressing any button the keypad is b...

Страница 14: ...KEYPAD SPECIFICATION Power supply 1 battery CR123A 3V Working time 3 years Frequency of operation 433 92 MHz Communication range up to 500m open air Communication one way Average current consumption 3...

Страница 15: ...ministrator the user with the highest access level They can both arm and disarm the system as well as access and make changes in all user functions presented in chapter 9 User s Functions and its subs...

Страница 16: ...e remote control If during the configuration of the remote control the arm immediately function was assigned to the any button pressing this button will fully arm immediately omitting time for exit 7...

Страница 17: ...r the exit time passes 7 4 1 2 Sleep mode Arming partitions in sleep mode is sensible when the partition has at least one night line assigned whether switched off during the night or delayed In order...

Страница 18: ...rol arming was assigned to the locked padlock button as the central enables assigning remote buttons to various functions it is possible to configure arming with a different button If exit time has be...

Страница 19: ...FULL MODE SLEEP MODE STAY MODE 7 5 1 2 Quick arming with partition selection To arm the selected partitions without entering the code three button combinations can be used The table below shows method...

Страница 20: ...odes and a long sound signal Additionally lit diodes 1 to 8 will indicate system errors This condition will last for 10 seconds If failures cannot be repaired quickly press to arm the system Pressing...

Страница 21: ...in to blink depending on which partition the triggered spot was assigned to and which mode the system armed in e g blinking of diode 2 means that a detector assigned to partition two was triggered and...

Страница 22: ...emote Press the remote button marked with the open padlock symbol assigned to the system disarming function NOTE it is assumed that during configuration of the remote disarming was assigned to the ope...

Страница 23: ...42 EN 8 3 ALARM MUTE 1 To mute deactivate the alarm enter the code and press 3 beeps will confirm the code Also the system will be disarmed 2 In order to identify the alarm type please refer to 9 1 A...

Страница 24: ...fter assigned delay time will cease to be shown on the keypad diodes will turn off The user will retain access to state of the alarm memory from inputs by entering the 3 function until he chooses to d...

Страница 25: ...larm history If no diode is lit in the alarm history but the ALARM diode continues to blink it means that an alarm was triggered in the system by another source than an entry line You can access the O...

Страница 26: ...B C and or D mean that inputs assigned to them are sabotaged Diodes switched off means there is no sabotage in the given group Switch between groups using the button To return to the main failure bran...

Страница 27: ...ne blocking function allows de activating stand by mode of any zones or bypassing any damaged lines Also zones which are not in stand by mode and which the user has access to can be blocked Zones rema...

Страница 28: ...to the monitoring station It can be enabled disabled by enter Administrator code Blinking of diode belonging to a group from A to D means that it is currently being shown To enable disable the chime...

Страница 29: ...user has been added correctly you will hear a triple confirmation tone otherwise you will hear a continuous signal 9 7 ARMING ONLY USER CAN T DISARM THE SYSTEM This function disables the ability of se...

Страница 30: ...the user to be deleted within your selected group group A B C or D numbers from 1 to 8 the number will start blinking and press to confirm or to exit without saving changes 4 If the user has been dele...

Страница 31: ...igned to the partition which the user who entered the code has access to Diodes switch off when the corresponding detector is triggered By pressing the button the user can switch between groups and ch...

Страница 32: ...rm Panic alarm activating the break in alarm Note for the emergency buttons to work it is necessary to be in arm disarm ready mode and wait at least 10 seconds since last 0 9 key press You can also pr...

Страница 33: ...ts of commands are given in square brackets This means that they are optional fields Acquiring the state of partitions Command syntax XXXX GETARMED Command description Acquiring the information which...

Страница 34: ...ber the numbers from 1 to 32 OUTPUT Setting the name of output corresponding to the indicated number the numbers from 1 to 3 USER Setting the name of user with the specified number the numbers from 1...

Страница 35: ...indicated number the numbers from 1 to 32 OUTPUT Acquiring the name of output corresponding to the indicated number the numbers from 1 to 3 USER Acquiring the name of user with the specified number t...

Страница 36: ...be send Example 1234 SETTELNUM 3 800123456 Feedback message description SETTELNUM OK command accepted SETTELNUM ERROR command rejected by the system Getting the phone number Command syntax XXXX GETTEL...

Страница 37: ...the text message Example 1234 SETMESSAGE 4 Robbery Feedback message description SETMESSAGE OK command accepted SETMESSAGE ERROR command rejected by the system Getting the content of text message Comma...

Страница 38: ...pter TELNUM ten digit chain of zeroes and ones Each digit counting from the left represents an index of the phone number first digit for the first phone number second digit for the second number and s...

Страница 39: ...sage description GETUSERSMS EVENT TELNUM MSG_ID information about text message and phone number assinged to the event GETUSERSMS EVENT ERROR command rejected by the system Getting delay between disarm...

Страница 40: ...s 1 32 INPUT1 TAMPEREND to INPUT32 TAMPEREND Sabotage of zones 1 32 ended INPUT1 LOCK to INPUT32 LOCK Bypass of zones 1 32 INPUT1 UNLOCK to INPUT32 UNLOCK Bypass of zones 1 32 ended OUTPUT1 ON to OUTP...

Страница 41: ...arted KEYPAD FIRE END Fire alarm ended JAMMING BEGIN GSM jamming JAMMING END GSM jamming ended DETECTOR1 LOST to DETECTOR32 LOST Detector 1 32 signal lost DETECTOR1 OK to DETECTOR32 OK Detector 1 32 s...

Страница 42: ...te Version Firmware Description 2017 09 20 v1 0 2 8 6 First version of the manual 2018 02 20 v1 2 2 9 1 Added chapters User categories Arming only user 2018 07 26 v1 3 2 10 0 Added a new response type...

Отзывы: