43
CONFIGURATION OF MASTER- SLAVE PRODUCTS EBERG REQU+ VERSION
Verify that the master unit doesn’t have other products connected to the terminals (C1 and C2), then proceed with
the powering. After the first 10 seconds while the red LED will be on, the product will be automatically configured
as master.
DO NOT PRESS ANY BUTTONS ON THE REMOTE CONTROL DURING THE CONFIGURATION
In order to verify that the configuration is ok:
1.
after the first 10 seconds the red LED switches off
2.
wait for the master configuration signal, ie a flash of the red LED
3.
press the button “AUTO”
If the red LED gives the signal corresponding to the “AUTO” mode (white/red blinking), the product is correctly
configured as MASTER. Once the product is configured as MASTER unit, it is possible to start with the
configuration of the SLAVE 1.
DO NOT PRESS ANY BUTTONS ON THE REMOTE CONTROL DURING THE CONFIGURATION OF SLAVE UNITS
Make sure the MASTER unit starts running before turning on the next unit (SLAVE) through the “0/1” switch in
order to give time to MASTER unit to configure the SLAVE products in the desired sequence.
Turn on, through main switch, all the SLAVE units in sequence as explained below only after that the previous
unit has actually started running.
1) Master Unit
2) Slave 1 which runs in the opposite direction of the Master
3) Slave 2 which runs in the same direction of the Master
4) Slave 3 which runs in the opposite direction of the Master ….
IN CONFIGURATION PHASE, SLAVE UNITS AFTER THE FIRST 10 seconds IN WHICH THE RED LED IS ON, WILL
NO LONGER MAKE ANY VISUAL NOTICE.
ATTENTION
If the product is not correctly configured (MASTER or SLAVE), the RESET function can be used. In this way the
product can be brought back to original manufacturing conditions. This procedure is explained in the
command/control manual.