2c) EBERG REQU R+ VERSION
POWER SUPPLY CONNECTION
Before proceeding with the connection make sure that the wires (Live and Neutral) are inside the area specifically
obtained in the wall.
Attention: When installing more devices as MASTER-SLAVE configuration, be sure to keep a minimum distance of
3 meters and a maximum distance of 20 meters, while obtaining optimal communication among the units.
The wall material (such as bricks, reinforced concrete), may have influence on the distance.
Take the internal wall-mounting part (4i) and the tools
necessary to connect the main supply to the terminal box.
Connect properly and safely the Live wires to the terminal
block identified as “N” and “L”.
Switching ON and OFF can be run by remote. To control the
product with recessed switch, it’s necessary, during
operation, that switches are always set on 1, as shown in the
picture (Y).
To turn on the product through wall switch, connect a bipolar
switch in sequence to “L” and “N”, as shown in the picture
(a).
Product can be connected to the network home automation
by serializing the main supply to set switching ON and OFF.
Connections must be done as shown below: