5 Installation
5.4 Mounting
MICRO PANEL XV200
10/2011 MN04802007Z-EN
www.eaton.com
39
5.4.1
Mounting the device
1
Select the mounting position of the device as described in Chapter 5.2.2 Requirements for the
mounting position,
22.
2
Prepare a mounting cutout for the device at the selected position:
Mounting cutout 198
×
142 mm (±1 mm)
Material thickness at the mounting cutout 2…5 mm
3
Insert the sealing strip supplied in the groove (A) on the rear of the device front plate and cut it so
that the join is tight.
Fig. 17 Mounting cutout for 5.7" devices
CAUTION
Poor sealing
Poor sealing resulting from the twisting of the sealing strip or due to a gap between
the ends of the sealing strip.
The join of the sealing strip must be positioned on the bottom of the device.
Do
not
twist the sealing strip when it is inserted.
Cut the sealing strip to a suitable length so that the join is tight.
198.0
+1/-1
142.0
+1/-1
Содержание XV200
Страница 1: ...Operating Instructions 10 2011 MN04802007Z EN replaces M001089 08 03 2010 XV200 MICRO PANEL...
Страница 6: ...1 General 1 3 Additional documentation 6 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 10: ...2 Device description 2 7 Designation 10 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 18: ...3 Safety regulations 3 4 Device related hazards 18 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 20: ...4 Operating and indication elements 4 1 Overview 20 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 42: ...5 Installation 5 4 Mounting 42 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 46: ...6 Operation 6 3 Switching off the device 46 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...
Страница 52: ...7 Maintenance and service 7 4 Troubleshooting 52 MICRO PANEL XV200 10 2011 MN04802007Z EN www eaton com...