8 Technical data 

8.1 Dimensions for XP-503 with 25.65 cm (10.1") display 

58

 

XP-503

    12/2014 MN048014-EN    www.eaton.com 

8.1.2

 

Device dimensions 

XP-503-10 

 

 

 

Abb. 13

 

XP-503-10 – Device dimensions 

 

 

ISO 2768mK  

general tolerances  

Содержание XP-503

Страница 1: ...Manual 12 2014 MN048014 EN XP 503 Panel PC...

Страница 2: ...dition of this document is the original manual Translated instructions All editions of this document other than those in German language are translations of the original manual Redaction Manfred H ppi...

Страница 3: ...uisites for proper operation 14 3 4 Device specific hazards 15 4 Installation 19 4 1 Safety instructions 19 4 2 Unpacking and checking the package contents 19 4 3 Storage and transportation 19 4 4 Ins...

Страница 4: ...instructions 53 6 2 Maintenance 53 6 2 1 Cleaning the capacitive touch panel 53 6 2 2 Battery 53 6 3 Repairs 54 7 Storage transport and disposal 55 7 1 Safety instructions 55 7 2 Storage 55 7 3 Trans...

Страница 5: ...rsonal safety and must be read and understood by everyone who will be working with the device WARNING Incomplete manual copies Working with individual pages taken out from the manual may lead to bodil...

Страница 6: ...1 General 1 3 Additional documentation 6 XP 503 12 2014 MN048014 EN www eaton com...

Страница 7: ...technology These devices are available in three widescreen display sizes 10 1 15 6 and 21 5 Their slim design featuring a non reflective glass front delivers a modern look The robust scratch resistant...

Страница 8: ...lileo Open Runtime License XP 503 15 A10 A00 1B 174475 21 5 widescreen industrial panel PC Galileo PCT Multitouch 1 65 GHz CPU 4GB RAM Min 32 GB of internal memory Min 4 GB of CFast removable memory W...

Страница 9: ...signation Nameplate The device has a nameplate on the back This nameplate makes it possible to identify the device and includes the following information Manufacturer Part Number Required power supply...

Страница 10: ...2 Description of device 2 4 Designation 10 XP 503 12 2014 MN048014 EN www eaton com...

Страница 11: ...cannot eliminate all potential hazards which is why it is necessary for you to be aware of all hazards and residual risks Do not run the device unless it is in perfect technical condition Make sure to...

Страница 12: ...situation that could result in death or serious injury if it is not avoided CAUTION CAUTION signal word Indicates a potentially hazardous situation that could result in minor or moderate injury if it...

Страница 13: ...and risks associated with the device 3 3 3 Manual Make sure that every person who will be working with the device regardless of the lifecycle stage involved has read and understood the relevant secti...

Страница 14: ...ructions in it The required ambient conditions must be met Maintenance work must be carried out correctly Potentially explosive atmosphere Zone 22 The ground resistance of accessible metal parts must...

Страница 15: ...109 ohms When used in a potentially explosive atmosphere Zone 22 the environment has to be designed to avoid any bunch discharge Make sure that the device is not exposed to dangerous impacts and other...

Страница 16: ...rgized Avoid writing to SSDs HDs and CFast cards as much as possible Reasons The number of write cycles for SSDs HDs and CFast cards is limited If there is a voltage drop while a write operation is in...

Страница 17: ...vice s lifespan Protect the device from direct sunlight and lamps with UV radiation CAUTION Cleaning the device The device can be damaged by pointy or sharp objects as well as by liquids Do not use po...

Страница 18: ...3 Safety instructions 3 4 Device specific hazards 18 XP 503 12 2014 MN048014 EN www eaton com...

Страница 19: ...with the device Verify Check the package contents for visible transit damage Use the package insert to make sure that the contents are complete 4 3 Storage and transportation The XP 503 is sturdily b...

Страница 20: ...in the Technical data chapter 4 4 2 Aeration and de aeration Do not block the ventilation openings when mounting the device They are designed to allow air to circulate in order to cool the device The...

Страница 21: ...ly vertical position make sure that air will still be able to circulate properly through the openings in the housing Example XP 503 21 The following also applies to other device versions as applicable...

Страница 22: ...ust be installed added An IP65 degree of protection will only be ensured if the control panel is stiff enough the device is properly mounted using its holding brackets and the gasket has a proper seat...

Страница 23: ...ked into the display housing sideways and screwed against the control panel door Together with the polyurethane foam gasket these holding brackets are the main element involved in achieving an IP65 de...

Страница 24: ...and signals have the required values CAUTION Safely diverting electrical interference currents The device and the control panel must be connected to a central earth point with as short a conductor le...

Страница 25: ...DC supply for integrated DC DC converter The applied voltage must meet the requirements for safety extra low voltages SELV set forth in IEC 60950 and in connection with the UL listing the requirement...

Страница 26: ...nductor cable and plug it into the socket at the bottom of the computer housing Pay attention to the polarity Connect the power supply cable to a 24 V power supply that meets the requirements for safe...

Страница 27: ...2 LEDs CAT5e 6 Pin Signal Description Input Output 1 TxD Transmit O 2 TxD Transmit O 3 RxD Receive I 4 N C not used 5 N C not used 6 RxD Receive I 7 N C not used 8 N C not used LED yellow Link LED gre...

Страница 28: ...host to device Tab 5 USB 3 0 2 x USB 3 0 4 8 3 DVI I interface DVI I interface conforming to the DVI I dual link standard for connecting with a digital or analog signal an external display unit DVI I...

Страница 29: ...3 TXD TX N C 4 DTR TX N C 5 GND GND GND 6 DSR N C N C 7 RTS N C N C 8 CTS N C N C 9 RI N C N C Tab 7 RS 485 232 Default setting half duplex RS 485 RS 232 One serial interface on a 9 pole SUB D plug t...

Страница 30: ...4 Installation 4 8 External connections 30 XP 503 12 2014 MN048014 EN www eaton com...

Страница 31: ...e to electrostatic discharges Because of this it is necessary to take precautions whenever handling the cards Please refer to the guidelines for electrostatic sensitive components for more information...

Страница 32: ...3 15 The following also applies to other device versions as applicable Unscrew the four screws on the computer housing cover Torx pan head screws without plain unthreaded shank RHS TORX Zn M3 x 5 ISO...

Страница 33: ...Commissioning and operation 5 1 Adding expansions to the XP 503 XP 503 12 2014 MN048014 EN www eaton com 33 Close When closing the device follow the same steps you used to open it but in opposite orde...

Страница 34: ...he housing does not need to be opened in order to access these ports Example XP 503 15 The following also applies to other device versions as applicable Interfaces 2 x Ethernet 2 x USB 3 0 DVI I RS 48...

Страница 35: ...mputer housing Example XP 503 15 The following also applies to other device versions as applicable Bottom of housing Abb 9 Connections for peripherals Num ber Interface Plug design 1 DVI I display por...

Страница 36: ...e connected to the serial ports RS 232 The matching mouse driver must be installed and configured before being able to use the mouse USB mouse A USB mouse can be connected to one of the USB ports It m...

Страница 37: ...ot can be accessed at the bottom of the computer housing The card adapter is screwed onto the computer housing s cover and is connected to a SATA interface on the computer board A cover prevents the c...

Страница 38: ...the power supply If you install a card adapter make sure that you use the CFast cards compatible with it A cover must be used to protect the card from falling out If you release the card from the adap...

Страница 39: ...3 15 The following also applies to other device versions as applicable Loosen the thumbscrew knurled head screw and remove the CFast adapter slot s cover To insert a card push it in until you feel it...

Страница 40: ...using a touch panel with multi touch capabilities There is always the possibility of an operator making errors when using the touch panel These errors may result in bodily injury or property damage Th...

Страница 41: ...re using the device check which types of potential soiling may accumulate on the touch panel and which functions may be triggered incorrectly as a result WARNING Potential damage when installing and o...

Страница 42: ...ically use a capacitive touch panel stylus If using your fingers Make sure to only use your fingertips Do not use your fingernails to operate the touch panel Do not use thick gloves when operating the...

Страница 43: ...apabilities touching the touch panel once will cause the operating system to resume i e trigger a wake up event If the touch panel is displaying available functions before the screen saver starts runn...

Страница 44: ...touch panel e g saline solution on the glass panel Avoiding static contact and continuing to run intended functions After approx 10 seconds touch the corresponding icon on the touch panel again and c...

Страница 45: ...that data and operating system files cannot be modified by anyone or corrupted by unexpected power disruptions As a result you can be confident that the XP 503 meets your rigorous industrial environme...

Страница 46: ...r to save desired data changes to the C drive the Protect Mode Save operation must be run extensive changes to C drive software installations must be executed with Protect Mode disabled Attention Exte...

Страница 47: ...be disabled and while in this mode the XP unit will behave like any other Windows PC meaning that it is subject to all forms of malware including viruses and adware and it must be shut down through th...

Страница 48: ...password from the User Accounts utility in Control Panel Start Control Panel User Accounts Once the Administrator password has been successfully modified you must follow the Account Auto Logon Feature...

Страница 49: ...49 Following dialog box appears Use the Check box Users must enter a user name and password to use this computer to enable disable the Auto Logon feature Check box checked Auto Logon is not activated...

Страница 50: ...ps no gloves Option 2 Gloves Sensitivity setting for controlling the touch panel while wearing gloves Option 3 EMC No functional restrictions if EMC interference is up to 20 higher than normal e g hig...

Страница 51: ...bedded Standard 7 XP 503 12 2014 MN048014 EN www eaton com 51 Once the program is successfully completed the following line will appear Firmware update Success The program will return to the starting...

Страница 52: ...device selection Galileo Open from the development PC For further information on these tools consult the Galileo software manuals 5 6 5 License Eaton Visual Designer Runtime XP 503 device types which...

Страница 53: ...g the capacitive touch panel when soiled 6 2 1 Cleaning the capacitive touch panel CAUTION Cleaning the device The device can be damaged by pointy or sharp objects as well as by liquids Do not use any...

Страница 54: ...12 2014 MN048014 EN www eaton com 6 3 Repairs The device should only be opened by the manufacturer or by an authorized repair center For repairs please contact your vendor or Eaton s Technical Suppor...

Страница 55: ...chapter 3 Safety instructions Chapter 3 contains important information regarding your own personal safety 7 2 Storage The ambient conditions for storage need to be met 7 3 Transport When transporting...

Страница 56: ...e RAL 9006 white aluminum Computer housing Galvanized sheet steel Sheet thickness 1 mm Cover glass Tempered glass across the entire surface tempered soda lime glass Non glare surface chemically microe...

Страница 57: ...nsions for XP 503 with 25 65 cm 10 1 display XP 503 12 2014 MN048014 EN www eaton com 57 8 Technical data 8 1 Dimensions for XP 503 with 25 65 cm 10 1 display 8 1 1 Front dimensions XP 503 10 Abb 12 X...

Страница 58: ...nical data 8 1 Dimensions for XP 503 with 25 65 cm 10 1 display 58 XP 503 12 2014 MN048014 EN www eaton com 8 1 2 Device dimensions XP 503 10 Abb 13 XP 503 10 Device dimensions ISO 2768mK general tole...

Страница 59: ...Dimensions for XP 503 with 25 65 cm 10 1 display XP 503 12 2014 MN048014 EN www eaton com 59 8 1 3 Fitting dimensions XP 503 10 Recommended mounting cutout Abb 14 XP 503 10 Fitting dimensions ISO 2768...

Страница 60: ...8 2 Dimensions for XP 503 with 39 6 cm 15 6 display 60 XP 503 12 2014 MN048014 EN www eaton com 8 2 Dimensions for XP 503 with 39 6 cm 15 6 display 8 2 1 Front dimensions XP 503 15 Abb 15 XP 503 15 F...

Страница 61: ...nical data 8 2 Dimensions for XP 503 with 39 6 cm 15 6 display XP 503 12 2014 MN048014 EN www eaton com 61 8 2 2 Device dimensions XP 503 15 Abb 16 XP 503 15 Device dimensions ISO 2768mK general toler...

Страница 62: ...Dimensions for XP 503 with 39 6 cm 15 6 display 62 XP 503 12 2014 MN048014 EN www eaton com 8 2 3 Fitting dimensions XP 503 15 Recommended mounting cutout Abb 17 XP 503 15 Fitting dimensions ISO 2768m...

Страница 63: ...8 3 Dimensions for XP 503 with 54 6 cm 21 5 display XP 503 12 2014 MN048014 EN www eaton com 63 8 3 Dimensions for XP 503 with 54 6 cm 21 5 display 8 3 1 Front dimensions XP 503 21 Abb 18 XP 503 21 F...

Страница 64: ...nical data 8 3 Dimensions for XP 503 with 54 6 cm 21 5 display 64 XP 503 12 2014 MN048014 EN www eaton com 8 3 2 Device dimensions XP 503 21 Abb 19 XP 503 21 Device dimensions ISO 2768mK general toler...

Страница 65: ...Dimensions for XP 503 with 54 6 cm 21 5 display XP 503 12 2014 MN048014 EN www eaton com 65 8 3 3 Fitting dimensions XP 503 21 Recommended mounting cutout Abb 20 XP 503 21 Fitting dimensions ISO 2768m...

Страница 66: ...m Cover glass Tempered glass across the entire surface tempered soda lime glass Non glare surface chemically microetched gloss 85 Designer bezel with direct to glass printing RAL 9005 jet black Thickn...

Страница 67: ...Screen size diagonal 39 6 cm 15 6 Visible screen area 344 232 mm x 193 536 mm Display resolution W x H WXGA 1366 x 768 pixels Format 16 9 Viewing range left right above below normally 85 85 80 80 Colo...

Страница 68: ...memory 1 x base 204 pin DDR3 SO DIMM 1066 1333 MHz max 8 GB 4 GB 1 x 4 GB DDR3 1333 SDRAM SO DIMM External Interfaces 2 x Ethernet 10 100 1000 MBit s 2 x USB 3 0 1 x DVI I 1 x serial RS 485 232 config...

Страница 69: ...ounting position 0 C to 50 C system with CFast SSD mSATA memory with natural convection 5 C to 50 C system with HDD with natural convection Storage 20 C to 60 C Relative humidity 10 90 non condensing...

Страница 70: ...61000 6 4 2007 Devices meeting this standard may not be used in residential areas Interference immunity As per EN 55024 2010 and EN 61000 6 2 2005 EN 61131 2 2007 Product safety UL 508 CSA C22 2 No 1...