4 Installation
4.8 External connections
XP-503
12/2014 MN048014-EN www.eaton.com
29
4.8.4
Serial interfaces
RS 485/232
One serial interface on a 9-pole SUB-D plug that can be used as an RS 232, RS 422, or RS 485
port, configurable in the BIOS.
1 × SUB-D plug,
9-pole
Pin RS 232
RS 422
RS 485
1 DCD
RX +
DATA –
2 RXD
RX –
DATA +
3 TXD
TX +
N.C.
4 DTR
TX –
N.C.
5 GND
GND
GND
6 DSR
N.C.
N.C.
7 RTS
N.C.
N.C.
8 CTS
N.C.
N.C.
9 RI
N.C.
N.C.
Tab. 7
RS 485/232
Default setting: half-duplex RS 485
RS 232
One serial interface on a 9-pole SUB-D plug that can be used as an RS 232 port.
1 × SUB-D plug,
9-pole
Pin Signal
Description
Input/Output
1 DCD
Data Carrier Detect
I
2 RXD
Receive Data
I
3 TXD
Transmit Data
O
4 DTR
Data Terminal Ready
O
5 GND
Signal Ground
---
6 DSR
Data Set Ready
I
7 RTS
Request to Send
O
8 CTS
Clear To Send
I
9 RI
Ring Indicator
I
Tab. 8
RS 232
Содержание XP-503
Страница 1: ...Manual 12 2014 MN048014 EN XP 503 Panel PC...
Страница 6: ...1 General 1 3 Additional documentation 6 XP 503 12 2014 MN048014 EN www eaton com...
Страница 10: ...2 Description of device 2 4 Designation 10 XP 503 12 2014 MN048014 EN www eaton com...
Страница 18: ...3 Safety instructions 3 4 Device specific hazards 18 XP 503 12 2014 MN048014 EN www eaton com...