TRSM0940
Removal and Installation
|
Input Shaft Speed Sensor
Input Shaft Speed Sensor Installation
Important:
Clean the mounting surface on the housing and
remove any burrs or sharp edges.
Important:
Lubricate the O-ring with Eaton Fuller silicone
71214 or equivalent.
1.
Using a smooth, twisting motion, fully insert the Input
Shaft Speed Sensor in the Transmission Shift Bar
Housing opening.
2.
Using a 3/8” socket, install the retaining bolt and
tighten to 8–10 lb-ft (11–13 N•m).
3.
Reconnect the Transmission Harness to the Input Shaft
Speed Sensor or pigtail connector, if equipped.
!
!