2022.10.7
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
73
TRSM0940
Auxiliary Section Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
10.
Loosen the 15/16” cap screw and retainer on the Out-
put Shaft. Do not remove the cap screw.
Note:
To prevent the counter shafts from turning, place
a shop rag or equivalent between the splitter gear and
one counter shaft.
11.
Using a soft bar and maul, drive the Output Shaft for-
ward far enough to partially unseat the bearing.
12.
Support the Auxiliary Countershaft and remove the
strap from the rear of the Auxiliary Case Housing
13.
Repeat process to remove 2nd Auxiliary Counter Shaft.
Содержание UltraShift PLUS