2022.10.7
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
37
TRSM0940
Auxiliary Section Service Procedures
|
LAS/VAS Auxiliary Section Assembly and Installation
3.
Subtract the thickness of feeler gauges needed to fit in
between the Auxiliary Case and Auxiliary Counter Shaft
Covers from 0.100”. Use that number to pick a shim
that will allow for end-play of within 0.001”–0.005”.
Note:
Example: 0.042" of feeler gauges fit in between
Auxiliary Case and the Auxiliary Counter Shaft Bearing
Cover. Subtract 0.042" from 0.100" which equals
0.058". A shim of 0.052"–0.055” would be required for
the 0.003"–0.005” end-play. (If the required thickness
shim does not exist, use the closest undersized shim.)
4.
Install required shim into bearing bore, Install new
gasket between the Main Case and Auxiliary Case.