![Eaton UltraShift PLUS Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/eaton/ultrashift-plus/ultrashift-plus_service-manual_3828061094.webp)
2022.10.7
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
91
TRSM0940
Auxiliary Section Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
4.
Apply Eaton Sealant #71205 or equivalent to the 19
retaining cap screws. Secure the Auxiliary Section to
the main case. Torque to 35-45 lb-ft
Auxiliary Countershaft Shimming and
Installation
1.
Remove the Auxiliary Countershaft support straps and
install a 0.100” shim between the cover and Auxiliary
Countershaft. Use two of the counter shaft bearing
cover bolts and torque bolts to 7 lb-in. Spin the Output
Shaft multiple times to assist in seating the bearing
races. Ensure cap screws are still torqued at 7 lb-in.
2.
Using feeler gages, measure the gap between the Aux-
iliary Countershaft covers and the Auxiliary Case. Use
multiple positions closest to the cap screws.
Содержание UltraShift PLUS
Страница 265: ......