![Eaton UltraShift PLUS Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/eaton/ultrashift-plus/ultrashift-plus_service-manual_3828061095.webp)
92
© 2022 Eaton Cummins Automated Transmission Technologies. All rights reserved.
2022.10.7
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
|
Auxiliary Section Service Procedures
TRSM0940
3.
Subtract the thickness of feeler gauges needed to fit in
between the auxiliary case and auxiliary counter shaft
covers from 0.100". Use that number to pick a shim
that will allow for end-play of within 0.001"–0.005".
Note:
Example: 0.042" of feeler gauges fit in between
auxiliary case and the auxiliary Counter Shaft bearing
cover. Subtract 0.042" from 0.100" which equals
0.058". A shim of 0.052"–0.055" would be required for
the 0.003"–0.005" end-play. (If the required thickness
shim does not exist, use the closest undersized shim.)
4.
Install required shim into bearing bore. Install new
Auxiliary Countershaft gaskets and install Auxiliary
Countershaft Covers.
Range and Splitter Cylinder Cover Installation
1.
Position new gasket on the Range Cylinder Cover
mounting surface.
2.
Install Range Cylinder Cover. Torque cap screws to
30-35 lb-ft.
3.
Position new gasket on the Splitter Cylinder Cover
mounting surface.
4.
Install Splitter Cylinder Cover. Torque cap screws to
30-35 lb-ft.