VCS/VMS Auxiliary Section Assembly and Installation
6.
Place the Low Range Gear Assembly on its side. Drive
the pins through the lock washer using a punch and
hammer.
Note:
Make sure pins are installed below coupler thrust
surface.
7.
Position the Low Range Gear (Reduction Gear) on the
Output Shaft with the coupler facing forward on the
shaft.
8
.
Install the dowel pin on the shaft
9.
Position retainer washer on the front of the shaft.
10.
Install retainer nut on the front of the shaft. If reusing
nut, apply locking compound to the threads. New nuts
should have a pre-applied locking compound. Torque
to 180-210 lb-ft.