
2019.07.11
© 2017 Eaton. All rights reserved
118
TRSM0940
Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
Auxiliary Section Installation
1.
Attach the Auxiliary Section lifting bracket to the top of
the Auxiliary Case.
2.
Position a new Auxiliary Case Gasket on the mounting
surface of the Main Case.
3.
Install the Auxiliary Case Assembly onto the transmis-
sion Main Case dowel pins. Using the Output Shaft,
wiggle the auxiliary case forward until it is as far for-
ward as possible. Remove the auxiliary section lifting
bracket.
Содержание UltraShift PLUS Series
Страница 2: ...1 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Страница 4: ......
Страница 5: ...2019 07 11 2017 Eaton All rights reserved 4 TRSM0970 General Information...
Страница 6: ...5 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Страница 7: ...2019 07 11 2017 Eaton All rights reserved 6 TRSM0970 General Information...
Страница 8: ...7 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...
Страница 9: ...2019 07 11 2017 Eaton All rights reserved 8 TRSM0970 General Information...
Страница 10: ...9 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970...