2018.12.12
© 2017 Eaton. All rights reserved
50
TRSM0940
Service Procedures
|
VCS/VMS Auxiliary Section Removal and Disassembly
11.
If necessary, secure the Countershafts in a vise and
remove both the front and rear bearings from the
shafts with a bearing separator and jaw pullers.
12.
Remove the 1 ½” nut retainer that was loosened in step
6.
13.
Remove the washer and dowel pin from the Auxiliary
Mainshaft