Release Yoke and Cross-Shaft(s) Removal and Installation
|
Service Procedures
TRSM0940
3.
Install the upper Cross-Shaft into the bore.
4.
Slide yoke onto upper Cross-Shaft assembly and install
1 cap screw and lock washer by hand.
5.
Install lower Cross-Shaft assembly and install 1 cap
screw and lock washer by hand.
6.
If previously removed, install the O-ring onto the
Cross-Shaft Plug and then install the Cross-Shaft Plug
into the Transmission Housing and torque to 34–48
lb-ft (46–65 N•m).