117
© 2017 Eaton. All rights reserved
2019.07.11
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
|
Service Procedures
TRSM0940
3.
Position a new gasket between the Splitter Cylinder
and the Auxiliary Case Housing bore. Install the Splitter
Cylinder.
4.
Install new O-rings on the ID and OD of the piston.
Lubricate with silicone.
5.
Install new O-ring on the end of the yoke bar inside of
the cylinder housing.
6.
Install the piston into the Splitter Cylinder with the
recessed side facing the rear of the transmission.
7.
Secure piston with the 3/4 lock nut. Torque to 30-36
lb-ft (41-49N•m).