![Eaton SystemStak DGM-5-30 Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/eaton/systemstak-dgm-5-30-series/systemstak-dgm-5-30-series_manual_4122937007.webp)
EATON
DGM**-5 30 Design E-VLST-BB002-E April 2015
N-7
N
Basic Characteristics
Maximum flow
120 l/min (32 USgpm)
Pilot flow@ 50
°
C (120
°
F) and 315 bar (4500 psi)
400–700 ml/min (24 in
3
/min-43 in
3
/min)
Maximum operating pressure
315 bar (4500 psi)ar (450 psi)
Pressure overshoot
31 bar (450 psi)
Operating temperature
-0
°
to 80
°
C (32
°
to 180
°
F)
Weights
DGMC 2,9 kg (6.5 lbs) DGMC2 3,6 kg (7.9 lbs)
Response time: For conditions of 5 liters (300 in
3
) of oil under compression and a flow rate of 120 l/min (32 USgpm) typical response is:
Initial pressure
Final pressure
Response time
17 bar (250 psi)
35 bar (500 psi)
95 ms
35 bar (500 psi)
140 bar (2000 psi)
110 ms
35 bar (500 psi)
315 bar (4500 psi)
150 ms
Operating Data
Performance Data
DGMC-5 and DGMC2-5 Insertion Loss
Insertion Loss
Total change in pressure drop from through ports “P” “B”,
“A” and “T”caused by the addition of the SystemStak valve
to a hydraulic circuit. Insertion loss curves (see top left):
1. DGMC2-5-AT-**-(E)-BT-**-(E)-(RC)*-30
DGMC-5-AT-**-(E)-(RC)*-30
DGMC-5-BT-**-(E)(RC)-*-30
2. DGMC-5-PT-**-(E)-(RC)*-30
3. DGMC2-5-AB-**-BA-**-30
DGMC-5 and DGMC2-5 Vented Pressure (RC models only)
(Not applicable for crossport models)
DGMC-5 and DGMC2-5 Pressure Override
The pressure override chart (below) shows typical override of
different adjustment ranges at maximum settings.
The vented pressure chart (above) indicates flow from control
port to discharge port over relief element.
Pressure Drop bar
Pressure Drop ps
i
15
10
5
200
150
100
50
0
0
Flow l/min
Flow USgpm
20
40
60
80
100
120
5
10
15
20
25
30
1
2
3
Pressure bar
Pressure psi
20
15
10
250
200
150
100
0
0
Flow l/min
Flow USgpm
20
40
60
80
100
120
5
10
15
20
25
30
5
50
Pressure psi
Pressure bar
Pressure psi
200
150
100
4000
3000
2000
0
0
Flow l/min
Flow USgpm
20
40
60
80
100
120
5
10
15
20
25
30
50
1000
300
350
250
5000
G
F
B
A
Override at minimum (“P”) setting all models