EATON
DGM**-5 30 Design E-VLST-BB002-E April 2015
N-18
N
Operating Data
Performance Data
Insertion Losses
These curves show the typical pressure drop for each flow
path in the valve. The “P” port pressure drop is the pressure
drop for flow across the sequence valve spool in the fully
open position.
The total insertion loss for the valve must be calculated by
summing the losses through each of the four flow paths.
Pressure Override
Typical pressure override of the different pressure ranges at
minimum and maximum settings.
Pressure Drop bar
Pressure Drop psi
d
15
10
100
0
0
Flow l/min
Flow USgpm
20
40
60
80
100
120
5
10
15
20
25
30
5
50
25
20
Pressure bar
Pressure psi
200
150
100
4000
3000
2000
0
0
Flow l/min
Flow USgpm
20
40
60
80
100
120
5
10
15
20
25
30
50
1000
300
350
250
5000
150
200
250
300
350
“A” or “B” port
“P” port*
“T” port
“G” max.
“F” max.
“B” max.
“A” max.
Minimum setting
(all models)
*Spool held in open position
Basic Characteristics
Maximum flow
120 l/min (32 USgpm)
Pilot flow@ 50
°
C (120
°
F) and 315 bar (4500 psi)
400-500 ml/min (24-31 in
3
/min)
Maximum operating pressure
“A” models - 70 bar (1000 psi) * (inlet pressure) 50 bar (725 psi)
(reduced pressure) “B”, “F” & “G” models - 315 bar (4500 psi)
Leakage flow rate @ 50
°
C (120
°
F) and 315 bar (4500 psi)
80-200 ml/min (15-12 in
3
/min)
Operating temperature
-0
°
to 80
°
C (32
°
to 180
°
F)
Weights
3,5 kg (7.7 lbs)