![Eaton SystemStak DGM-5-30 Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/eaton/systemstak-dgm-5-30-series/systemstak-dgm-5-30-series_manual_4122937017.webp)
EATON
DGM**-5 30 Design E-VLST-BB002-E April 2015
N-17
N
SystemStak™ Internal Pilot Operated Sequence Valves
Functional Symbols
Model Code
DGMR1
General Description
These two-stage pressure operated valves are normally
closed to flow through the main spool flow path. When
system pressure reaches or exceeds the valve setting, the
main spool flow path opens. Pilot flow may be externally or
internally drained to tank.
Any pressure in the line to which these valves are drained is
additive to the valve pressure setting.
The valve pressure setting is adjustable by means of either
an adjustable screw containing an internal hex, a hand-adjust
knob, or a micrometer knob with keylock. Different spring
ratings cover an overall pressure range from 5 to 315 bar
(75-4500 psi).
P
P
T
B
T
B
T
A
T
A
B
B
A
A
DGMR1-5-
PP
-**-*-30
P
P
T
B
T
B
T
A
T
A
B
B
A
A
DGMR1-5-
PP
-**-E-*-30
G
G
DR
Valve function
Manifold or subplate mounted
sequence valve.
Interface
5 –
ISO 4401-AC-05-4-A, CETOP RP35H
Size 5 ANSI/NFPA D05
Port operated upon
P –
Pressure port
Pilot control
P –
Pressure port
Pressure range
A –
5 to 50 bar (75 to 725 psi)
B –
5 to 100 bar (75 to 1450 psi)
F –
5 to 200 bar (75 to 2900 psi)
G –
5 to 315 bar (75 to 4500 psi)
Adjustment device
H –
Knob adjuster
K –
Micrometer knob with keylock
W –
Screw with locknut
External drain
E –
External drain
Omit for internal drain models.
Gage port & thread type
Gage port (all models), external drain (E)
(optional).
B –
G 1/8” (1/8” BSPF)
S –
SAE-4 O-ring boss port
(0.4375-20 UNF-2B thread)
Design mumber - 30 series
Subject to change. Installation
dimensions unaltered for design
numbers 30 to 39 inclusive.
DGMR1 - 5 - P P - * * - (E) - * - 30
1
7
9
3
4
5
6
8
2
1
2
3
4
6
5
7
8
9