EATON
DGM**-5 30 Design E-VLST-BB002-E April 2015
N-19
N
Installation Dimensions
DGMR1-5-PP-**-30
Sequence Valve
mm (inches)
See page 37 for optional adjustment devices.
See page 38 for interface dimensions.
*External drain and gage port threads
“S” models - SAE-4 O-ring boss port
(0.4375-20 UNF-2B thread).
“B” models - G 1/8 (1/8 BSPF)
Note:
Back pressure in drain
is added to this setting for
internal drain models only.
* Gage port. External
connection port thread
60
(2.36)
10
(0.39)
30,5
(1.20)
48
(1.89)
“W” models (max. ext.)
Wrench size
11,5
(0.45)
ISO 4401-AC-05-4-A (NFPA D05)
Mounting surface
13,5
(0.53)
4 mounting holes
6,9 (0.27) through
9,50 (0.37) counterbore
46,5 (1.83) deep
for bolt extenders
(order separately)
BKE-6M-60M (M6 metric) or
BKE-4-60M (.2500-20 UNC).
Torque: 11,3-14,7 Nm
(100-130 lb. in.)
130
(5.12)
37
(1.46)
11,7
(0.46)
28,4
(1.12)
69,5
(2.74)
71,6
(2.82)
max.
20,4
(0.80)
Adjust clockwise to increase
pressure setting.
*External drain port. Plugged for internal drain
* Gage port. External
connection port thread
T
B
B
P
A
T
A
128
(5.04)
3rd angle
projection
13 (1/2”)
Hex key 4 (5/32”)