background image

S611 Soft Starter

ii

S611 Soft Starter

    MN03901003E—January 2012    www.eaton.com

Support Services

The goal of Eaton is to ensure your greatest possible satisfaction with the operation of our 
products. We are dedicated to providing fast, friendly, and accurate assistance. That is why 
we offer you so many ways to get the support you need. Whether it’s by phone, fax, or 
e-mail, you can access Eaton’s support information 24 hours a day, seven days a week. 
Our wide range of services is listed below. 

You should contact your local distributor for product pricing, availability, ordering, expediting, 
and repairs. 

Web Site 

Use the Eaton web site to find product information. You can also find information on local 
distributors or Eaton’s sales offices. 

Web Site Address 

www.eaton.com/electrical 

EatonCare Customer Support Center 

Call the EatonCare Support Center if you need assistance with placing an order, stock 
availability or proof of shipment, expediting an existing order, emergency shipments, product 
price information, returns other than warranty returns, and information on local distributors or 
sales offices. 

Voice: 877-ETN-CARE (386-2273) (8:00 a.m.–6:00 p.m. EST) 
FAX: 800-752-8602 
After-Hours Emergency: 800-543-7038 
(6:00 p.m.–8:00 a.m. EST) 

If you are in the U.S. or Canada, and have OI or PLC questions, you can take advantage of our 
toll-free line for technical assistance with hardware and software product selection, system 
design and installation, and system debugging and diagnostics. Technical support engineers 
are available for calls during regular business hours. 

Technical Resource Center 

Voice: 877-ETN-CARE (386-2273) (8:00 a.m.–5:00 p.m. EST) 

FAX: 828-651-0549 

e-mail: [email protected] 

European PanelMate Support Center 

This engineering company, located in Zurich, Switzerland, provides high-level quality 
support and repair assistance for your PanelMate products. You will receive technical 
and application support. 

For Customers in Europe, contact: 

BFA Solutions, Ltd. 
Voice: +41 1 806.64.44 (9:00 a.m.–5:00 p.m. CET) 

e-mail: [email protected] 

www.bfa.ch 

Repair and Upgrade Service 

Additional support is also available from our well-equipped Repair and Upgrade Service 
department. If you have questions regarding the repair or upgrade of an OI product, contact 
your local distributor. 

Repair and Upgrade Service (support for OI) 

Voice: 
877-ETN-CARE (877-386-2273) (8:00 a.m.–5:00 p.m. EST) 
414-449-7100 (8:00 a.m.–5:00 p.m. EST) 

FAX: 614-882-3414 

e-mail: [email protected] 

www.comoso.com

Содержание S611

Страница 1: ...S611 Soft Starter Quick Start Installation Guide Effective January 2012 Supersedes June 2011 www comoso com...

Страница 2: ...www comoso com...

Страница 3: ...MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECO...

Страница 4: ...E 386 2273 8 00 a m 6 00 p m EST FAX 800 752 8602 After Hours Emergency 800 543 7038 6 00 p m 8 00 a m EST If you are in the U S or Canada and have OI or PLC questions you can take advantage of our to...

Страница 5: ...tarter Do not attempt to lift the soft starter by the cover only Lug Installation Install the lugs below the bus bar to assure anti rotation Refer to figure Lug and Bolt Torque Support on this page Po...

Страница 6: ...ze Number of Conductors Mechanical Lug Ilsco Part Number Torque lb in Mechanical Lug Range Soft Starter Catalog Number Mechanical Lug Eaton Catalog Number 52A 6 AWG 1 TA 2 0 120 14 AWG 2 0 S611A052XXX...

Страница 7: ...ting Hole Dimensions Approximate Dimensions in mm Inches Frames A through D Frames E and F 70 0 2 76 464 7 18 30 110 0 4 33 10 0 0 39 70 0 2 76 80 0 3 15 90 0 3 54 80 0 3 15 155 0 6 10 562 0 22 13 10...

Страница 8: ...ive L Permissive N Start L Start N Reset L Reset Reset E Stop Maintained Momentary Comms Adapter Comms Modbus TB4 DeviceNet Modbus PROFIBUS TB5 Module Ground 24V D0 D1 Common N Tap Neutral L Tap Line...

Страница 9: ...on Operation LED list Navigates through display parameter list in Monitor mode Edit Save Selects Saves parameter values in Protection Operation modes Selects Advanced Con g Menu parameters Selects Sav...

Страница 10: ...rt time elapses Verify that the motor is not overloaded After suitable performance has been achieved with either method determine the starting time to bypass and set Soft Start Time at 1 25 times this...

Страница 11: ...45 67 Default value 36 60 33 57 Wye delta equivalent 27 52 19 44 Minimum for current limit 14 37 9 30 1 10 Minimum Application t Start t Stop u Start Breakaway Torque Remarks Crusher empty at start 20...

Страница 12: ...ch network controller verify that the unit is recognized by the system controller Comms Port B adapter module failed or disconnected 15 Power Pole Over Temperature SCR temperature is above limits Oper...

Страница 13: ...Incoming AC line voltage below trip threshold Incorrect mains supply voltage Connect to correct supply voltage Verify that mains voltage is within acceptable values Verify Motor Rated Voltage in the...

Страница 14: ...imbalance problem with mains Increase the Voltage Fault Imbalance parameters Disable the fault if the other issues cannot be resolved 33 Jam Soft starter in bypass Motor below rated RPM and or current...

Страница 15: ...www comoso com...

Страница 16: ...liable efficient and safe power is available when it s needed most With unparalleled knowledge of electrical power management across industries experts at Eaton deliver customized integrated solutions...

Отзывы: