2 Engineering
2.2 Electrical power network
DC1 Variable Frequency Drive
04/16 MN04020003Z-EN
www.eaton.com
37
2.2 Electrical power network
2.2.1 Mains terminal and configuration
DC1 variable frequency drives can be connected to and run on all neutral
point-grounded AC supply systems (TN-S, TN-C, TT grounding systems;
please refer to IEC 60364) without any limitations.
Figure 14: AC supply systems with earthed center point
The connection and operation of variable frequency drives to asymmetrically
grounded TN networks (phase-grounded delta network “Grounded Delta”,
USA) or non-grounded or high-resistance grounded (over 30
Ω
) IT networks is
only conditionally permissible (internal radio interference suppression filters).
DC1-…-A20N variable frequency drives can be connected to corner-
grounded systems or IT grounding systems (not grounded, insulated).
When versions featuring an internal radio interference suppression filter
(DC1-…
F
N-A20N, DC1-…
F
B-A20N) are connected to one of these systems,
the
EMC
screw(s) needs to be removed and the internal radio interference
suppression filter needs to be disconnected
TN-S
TN-C
TT
→
While planning the project, consider a symmetrical distribution
to the three main phase conductors, if multiple variable
frequency drives with single-phase supplies are to be
connected. The total current of all single phase consumers is
not to cause an overload of the neutral conductor (N-conductor).
→
Operation on non-earthed networks (IT) requires the use of
suitable insulation monitoring relays (e.g. pulse-code
measurement method)
→
In networks with an earthed phase conductor, the maximum
phase-earth voltage must not exceed 300 V AC.
→
Measures for electromagnetic compatibility are mandatory in a
power drive system, to meet the legal standards for EMC- and
Low Voltage Directive. Good earthing measures are a
prerequisite for the effective Use of further measures such as
screen earth kit or filters here. Without respective grounding
measures, further steps are superfluous.
L2
N
L1
L3
PE
L2
PEN
L1
L3
L2
N
L1
L3
Содержание PowerXL DC1
Страница 1: ...Manual PowerXL DC1 Variable Frequency Drives Installation Manual 04 16 MN04020003Z EN...
Страница 4: ...II...
Страница 114: ...3 Installation 3 9 Protection against electric shock 110 DC1 Variable Frequency Drive 04 16 MN04020003Z EN www eaton com...
Страница 176: ...7 Accessories 7 2 General accessories List 172 DC1 Variable Frequency Drive 04 16 MN04020003Z EN www eaton com...