6 Technical Data
6.2 Specific rated operational data
DC1 Variable Frequency Drive
04/16 MN04020003Z-EN
www.eaton.com
139
DC1-34…device series
Continue
Size
Symbol
Unit
014
018
024
030
039
046
Rated operational current
I
e
A
14
18
24
30
39
46
Overload current for 60 s every 600 s
i
l
A
21
27
36
45
58.5
69
Starting current for 2 s every 20 s
A
24.5
31.5
42
52.5
68.25
80.5
Apparent power at rated operation
400 V
S
kVA
9.67
12.47
16.63
20.76
26.99
31.83
Apparent power at rated operation
480 V
S
kVA
11.64
14.96
19.95
24.91
32.39
38.20
Assigned motor power
at 400 V, 50 Hz
P
kW
5.5
7.5
11
15
18.5
22
at 440 - 480 V, 60 Hz
P
HP
7.5
10
15
20
25
30
Power side (primary side):
Number of phases
3
3
3
3
3
3
Rated operating voltage
U
LN
V
380 V - 10 % - 480 V + 10 %, 50/60 Hz
342 - 528 V ±0 %, 48 - 62 Hz ±0 %
Input current (phase current)
I
LN
A
17.2
21.2
27.5
26.4
33.3
50.1
Minimum braking resistance
R
B
Ω
100
80
50
30
22
22
Switching frequency (pulse frequency)
Default Setting
f
PWM
kHz
8
8
8
8
8
8
Setting range
f
PWM
kHz
4 - 24
4 - 24
4 - 24
4 - 24
4 - 24
4 - 24
Maximum leakage current to earth
(PE),
Without motor
I
PE
mA
< 1
< 1
2.49
2.49
2.49
2.49
Efficiency
η
0.96
0.97
0.97
0.97
0.97
0.96
Heat dissipation at I
e
(150 %)
P
V
CO
223
304
446
607
728
801
fan, built-in
✓
✓
✓
✓
✓
✓
Size
FS3
FS3
FS3
FS4
FS4
FS4