6 Specifications
6.2 Specific rated operational data
DA1 Variable Frequency Drives
08/18 MN04020005Z-EN
www.eaton.com
157
DA1-35… series
Size
Symbol
Unit
054
065
078
105
130
150
Rated operational current
I
e
A
54
65
78
105
130
150
Overload current for 60 s every 600 s
I
L
A
81
97.5
117
157.5
195
225
Apparent power at rated operation
500 V
S
kVA
29.7
35.2
45.2
60.5
71.5
79.1
600 V
S
kVA
35.6
42.2
54.3
72.6
85.9
95
Rated motor output
500 V
P
kW
37
45
55
75
90
110
575 V
P
HP
50
60
75
100
125
150
Power input side (primary side):
Number of phases
three-phase
Rated voltage
U
LN
V
500 V -10 % - 600 V +10 %, 50/60 Hz
Input current (phase current)
I
LN
A
62.2
75.8
90.9
108.2
162
187
Minimum braking resistor
R
B
Ω
12
12
6
6
6
6
Switching frequency (pulse frequency)
Factory default setting
f
PWM
kHz
8
8
4
4
4
4
Settings range
f
PWM
kHz
4 - 24
4 - 24
4 -16
4 - 16
4 - 12
4 - 12
Maximum leakage current to earth (PE), without motor
I
PE
mA
–
–
–
–
–
–
Efficiency
η
0.97
0.97
0.97
0.97
0.97
0.97
Heat dissipation at I
e
P
V
W
1110
1350
1650
2250
2700
3300
Frame size
FS5
FS5
FS6
FS6
FS6
FS6