Pow-R-Line X  Retrofit Panelboards

Pow-R-Line X RetRofit PaneLboaRds

   MN014011EN   January 2020   eatoncanada.ca

Table 1.  P1RXL & P1RXB Panelboards

Main device

Circuits

Current

(amperes)

Minimum 

Height

(in / mm

Minimum 

width

(in / mm)

Minimum 

depth

(in / mm)

Lug

18

100

19.5 / 495

14.25 / 362

4.5 / 121

24

22.5 / 571

30

26.5 / 673

42

33.5 / 851

18

225

22 / 559

24

25 / 635

30

28 / 711

42

34 / 864

60

43 / 1092

Breaker (BAB)

18

60-100

19.5 / 495

30

26.5 / 673

42

33.5 / 851

Breaker (PD2 or 

PD3 Frame)

18

60-225

30 / 762

30

36 / 914

42

42 / 1067

Lug

24

400

48 / 1219

20.0 / 508

5.75 / 127

30
42

Table 2.  P2RXL & P2RXB Panelboards

Main device

Circuits

Current

(amperes)

Minimum 

Height

(in / mm

Minimum 

width

(in / mm)

Minimum 

depth

(in / mm)

Lug

18

100

19.5 / 495

14.25 / 362

4.75 / 121

24

22.5 / 571

30

26.5 / 673

42

33.5 / 851

18

225

22 / 559

24

25 / 635

30

28 / 711

42

34 / 864

60

43 / 1092

Breaker (GBH, GHB)

18

60-100

19.5 / 495

30

26.5 / 673

42

33.5 / 851

Breaker (PD2 or 

PD3 Frame)

18

60-225

30 / 762

30

36 / 914

42

42 / 1067

Lug

24

400

48 / 1219

20.0 / 508

5.75 / 127

30
42

Installation Criteria

The Eaton Pow-R-Line P1RX & P2RX panelboards are intended for use in the following list of panelboard enclosures and 

which meet the minimum size requirements listed in the tables below.

Содержание P1RX 240Vac Max

Страница 1: ...Pow R Line X Retrofit Panelboards Instruction Manual MN014011EN Effective January 2020 P1RX 240Vac Max P2RX 347 600Vac Max...

Страница 2: ......

Страница 3: ...1EN January 2020 eatoncanada ca Table of Content Installation Criteria 2 Safety Measures 3 Pre Installation Receiving Handling and Storage 4 Removal of Existing Panelboard Interior 4 Installation of R...

Страница 4: ...2 1067 Lug 24 400 48 1219 20 0 508 5 75 127 30 42 Table 2 P2RXL P2RXB Panelboards Main Device Circuits Current Amperes Minimum Height in mm Minimum Width in mm Minimum Depth in mm Lug 18 100 19 5 495...

Страница 5: ...ade all reasonable efforts to ensure that the instructions in this document are adequate and free of material errors and omissions Eaton will if necessary explain issues which may not be covered by th...

Страница 6: ...TALL AND OR SERVICE THIS EQUIPMENT Removal of Existing Panelboard Interior DO NOT work on electrical equipment while energized Verify power entering the equipment is de energized at the source Follow...

Страница 7: ...maintained per NECTM CECTM Care must be taken to ensure that the trim will completely cover openings in the enclosure If not using existing mounting hardware mark minimum of 8 mounting locations on th...

Страница 8: ...conductor into lug so the bare conductor fills the full length of the lug body Tighten lug then torque to levels indicated on the panelboard label If compression lugs are utilized and supplied with th...

Страница 9: ...uire ground fault protection for this installation Other GFP applications may be used including multi level ground fault protection Refer to the panelboard drawings and electrical construction drawing...

Страница 10: ...trim parts on the panelboard using hardware supplied by the manufacturer Take caution that conductors are not pinched between parts when installing the dead front cover and trim All parts should be al...

Страница 11: ...e all control power fusing and connections to products which will be damaged in this test This includes all components with control wire fusing Transient Voltage Surge Suppression Surge Protective Dev...

Страница 12: ...o maintain the equipment in satisfactory condition Maintain a permanent record of all maintenance activities and testing for future reference The condition of each panelboard should be recorded as a g...

Страница 13: ...RE ENERGIZE PANELBOARD After the panelboard has completely dried remove all materials and tools from the equipment Inspect all connections for damage and torque Re install all covers fillers dead fro...

Страница 14: ...le 4 Wire Bending Space Requirements for Cable Sizes Bolt Size Torque inch pounds Torque foot pounds Torque Newton Meters 10 30 2 5 3 4 65 5 4 7 3 5 16 130 10 8 14 7 3 8 240 20 27 1 600 50 67 8 Nation...

Страница 15: ...11 Pow R Line X Retrofit Panelboards Pow R Line X Retrofit Panelboards MN014011EN January 2020 eatoncanada ca Notes...

Страница 16: ...evard Cleveland OH 44122 United States Eaton com 2020 Eaton All Rights Reserved Printed in USA Publication No MN014011EN January 2020 Eaton is a registered trademark All trademarks are property of the...

Отзывы: