iv

INSTALLATION AND OPERATION INSTRUCTIONS

   MN280046EN   May 2016

The instructions in this manual are not intended as a 

substitute for proper training or adequate experience in the 

safe operation of the equipment described. Only competent 

technicians who are familiar with this equipment should 

install, operate, and service it.
A competent technician has these qualifications:
• Is thoroughly familiar with these instructions.
•  Is trained in industry-accepted high and low-voltage safe 

operating practices and procedures.

•  Is trained and authorized to energize, de-energize, clear, 

and ground power distribution equipment.

•  Is trained in the care and use of protective equipment 

such as arc flash clothing, safety glasses, face shield, hard 

hat, rubber gloves, clampstick, hotstick, etc.

Following is important safety information. For safe 

installation and operation of this equipment, be sure to read 

and understand all cautions and warnings.

Safety instructions

Following are general caution and warning statements that 

apply to this equipment. Additional statements, related to 

specific tasks and procedures, are located throughout the 

manual.

Safety for life

!

SAFETY

FOR LIFE

!

SAFETY

FOR LIFE

Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power

 series products. 

We actively promote safe practices in the use and maintenance of our products through our service literature, instructional 

training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, 

and service.
We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around 

high voltage lines and equipment, and support our “Safety For Life” mission.

Safety information

DANGER

Hazardous voltage . Contact with hazardous voltage will 

cause death or severe personal injury . Follow all locally 

approved safety procedures when working around high- 

and low-voltage lines and equipment . 

                

G103 .3

WARNING 

Before installing, operating, maintaining, or testing this 

equipment, carefully read and understand the contents 

of this manual . Improper operation, handling or 

maintenance can result in death, severe personal injury, 

and equipment damage .                                            

G101 .0

WARNING 

This equipment is not intended to protect human 

life . Follow all locally approved procedures and safety 

practices when installing or operating this equipment . 

Failure to comply can result in death, severe personal 

injury and equipment damage .                                  

G102 .1

WARNING 

Power distribution and transmission equipment must 

be properly selected for the intended application . It 

must be installed and serviced by competent personnel 

who have been trained and understand proper safety 

procedures . These instructions are written for such 

personnel and are not a substitute for adequate training 

and experience in safety procedures . Failure to properly 

select, install or maintain power distribution and 

transmission equipment can result in death, severe 

personal injury, and equipment damage .     

      

                G122 .3

This manual may contain four types of hazard statements:

DANGER 

Indicates an imminently hazardous situation which, if 

not avoided, will result in death or serious injury .

WARNING 

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury .

CAUTION 

Indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury .

CAUTION

Indicates a potentially hazardous situation which, if not 

avoided, may result in equipment damage only .

Hazard Statement Definitions

Содержание NOVA STS-15

Страница 1: ...NOVA STS 27 and NOVA STS 38 Single Tank Triple Single Electronically Controlled Recloser Installation and Operation Instructions COOPER POWER SERIES Reclosers MN280046EN Effective May 2016 Supersedes...

Страница 2: ...LAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT...

Страница 3: ...ing the recloser 4 Lifting the recloser 4 Remove recloser from service 6 Grounding the NOVA STS recloser 7 RECLOSER OPERATION 8 Vacuum interrupter 8 Mechanism tripping and closing 8 Electronic control...

Страница 4: ...EN May 2016 SERVICE INFORMATION 16 Service requirements 16 Discharge trip and close capacitor 16 Frequency of inspection 16 High potential withstand testing 17 Module flashover service 18 TROUBLESHOOT...

Страница 5: ...igh voltage lines and equipment and support our Safety For Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all...

Страница 6: ...incurred during shipment If damage is discovered file a claim with the carrier immediately Handling and storage Be careful during handling and storage of the recloser to minimize the possibility of da...

Страница 7: ...kV 38 kV Rated Continuous Current 630 A 630 A 630 A 630 A 630 A Short Circuit Current Symmetrical 12 5 kA 12 5 kA 12 5 kA 12 5 kA 12 5 kA Making Current Asymmetrical Peak 32 0 kA 32 0 kA 32 0 kA 32 0...

Страница 8: ...5 Flat Pad 4 hole 800 A maximum 121 4 75 Stud Type 1 125 12 threads 800 A maximum 82 3 25 Table 7 Terminal options continued Description B C NOVA STS 15 110 kV BIL 1008 39 75 733 29 NOVA STS 15 125 kV...

Страница 9: ...t in cuts and abrasions T258 1 3 Install the recloser Install the recloser in the appropriate Eaton s Cooper Power series pole or substation mounting frame See Figure 3 for moving and lifting instruct...

Страница 10: ...es and bypass switches are not required but are highly recommended as they facilitate switching and isolation Disconnect switches for AC sensing and power connections are necessary to isolate the Form...

Страница 11: ...ich will cause death or severe personal injury G108 1 WARNING Hazardous voltage Do not rely on the open position of the yellow operating handle or the contact position indicator it does not ensure tha...

Страница 12: ...ice Eaton recommends transporting Cooper Power series NOVA reclosers in the closed position to maxi mize the operational performance of the unit Grounding the NOVA STS recloser IMPORTANT In pole mount...

Страница 13: ...responds to trip and close commands from the control per the settings programmed in the control Refer to Service Information S280 70 7 Form 6 Triple Single Microprocessor Based Pole Mount Recloser Con...

Страница 14: ...der the sleet hood Note N When the recloser electronically operates to lockout the yellow operating handle will not drop down from under the sleet hood The yellow operating handle remains in the OPEN...

Страница 15: ...that the voltage is zero and the line has been de energized Always follow proper safety practices and use a separate detection method to verify a de energized condition Failure to do so can result in...

Страница 16: ...refer to Tables 9 and 10 These are entered in the System Configuration screen see Figure 12 When programming the Form 6 Triple Single control the PT connection must be set for a wye connection Also t...

Страница 17: ...uch the receptacle connections of the control voltage sensing cable If the recloser is energized and the control voltage sensing cable is disconnected from the recloser or the control a voltage clampe...

Страница 18: ...B phase b white black red black G H C phase a green black orange black J K C phase b blue black black white L M unused unused unused N P See Figure 6 A phase is designated as terminals 1 and 2 B phase...

Страница 19: ...Cable Range 800 A maximum 108 4 25 Flat Pad 2 hole 630 A maximum 114 4 5 Flat Pad 4 hole 800 A maximum 121 4 75 Stud Type 1 125 12 threads 800 A maximum 82 3 25 Table 14 Terminal options continued De...

Страница 20: ...e not included with the brackets Refer to Figure 14 Inboard arrester mounting accessory 374 14 75 min 523 20 5 650 25 5 395 15 5 650 25 5 523 20 5 395 15 5 285 11 25 469 18 5 1030 40 5 107 4 25 394 15...

Страница 21: ...it smoothly and do not allow the unit to shift Improper lifting can result in severe personal injury death and or equipment damage G106 3 2 Loosen bolts that secure the tank and remove the tank bottom...

Страница 22: ...s Solidly ground all equipment Failure to comply can result in death severe personal injury and equipment damage T221 5 CAUTION Radiation At voltages up to the specified test voltages the radiation em...

Страница 23: ...ized service center or your Eaton s Cooper Power series product representative Note N Test results for NOVA reclosers equipped with the internal voltage sensing option will be influenced by the source...

Страница 24: ...LOSE position Check all cables for proper connection Check the condition of the battery located in the control cabinet Refer to Service Information S280 70 7 Form 6 Triple Single Microprocessor Based...

Страница 25: ...se T Yellow Handle B phase P 53 V Common B phase B 53 V dc B phase W CT B phase b Voltage Sensor B phase G Trip C phase K Close C phase U Yellow Handle C phase R 53 V Common C phase C 53 V dc C phase...

Страница 26: ...LK WHT WHT ORG BRN P1 7 CT COM Optional Voltage Sensor VTC 28 V dc NO TRIP Yellow Handle CLOSE Common 28 V dc 53 V Common 53 V dc YEL RED P2 2 MS3 yellow handle NC Actuator Circuit Board P2 3 MS2 52b...

Страница 27: ...K CLOSE C L Common 28 V dc M Chassis Ground A N 53 V Common A P 53 V Common B R 53 V Common C S Yellow Handle A T Yellow Handle B U Yellow Handle C V CT A W CT B X CT C Y CT Common Z Opt Voltage Sens...

Страница 28: ...es Eaton com cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No MN280046EN May 2016 KA20480749 REV00 Eaton is a registered trademark All trademarks are property of their re...

Отзывы: