Configuring the Card
Eaton Network Card-MS User’s Guide P-164000100—Rev 1
www.eaton.com/powerquality
38
l
IPv6 Auto Config Enabled:
Authorizes (choose ’Enabled’) the card to obtain configuration of IPv6
parameters from an IPv6 router. In this case, no IPv6 parameters are editable.
l
IPv6 Address 1:
- If Auto Config is enabled, this field displays the first IPv6 address built from the IPv6 router (not editable).
- If Auto Config is not enabled, this field is editable and allows users to set a static IPv6 address.
Prefix length:
- If Auto Config is enabled, this field displays the prefix received from the router (not editable).
- If Auto Config is not enabled, this field is editable and allows setting a prefix.
IPv6 Gateway:
- If Auto Config is enabled, this field is empty and not editable.
- If Auto Config is not enabled, this field is editable and allows users to set the default gateway.
IPv6 Local Address:
Displays the IP local address of the card, built from the MAC address. This field is not
editable. This field is always available when the IPv6 is enabled.
IPv6 Address 2:
- If Auto Config is enabled, this field displays the second IPv6 address built from the IPv6 router (not
editable).
- If Auto Config is not enabled, this field is empty and not editable.
l
Firmware Upload:
When Firmware Upload is set to
Enabled
, the system authorizes remote updating of the
card’s embedded software. The default is
Enabled
.
l
Primary DNS Server:
Indicates the IP address of the main DNS server ensuring conversion of the domain
name to IP address.
l
Secondary DNS Server:
Indicates the IP address of the secondary DNS server, ensuring conversion of the
domain name to IP address if the primary DNS server is not available.
l
SMTP Server (for Email Notification):
Indicates the name or IP address of the local server with which the card
connects to send e-mail messages. You can fill in the field either as host + domain name (DNS resolution) or
directly with the IP address.
The default value is
smtpserver
. The card uses the standard port (25) for sending e-mail messages.
l
SMTP server authentication:
Optional. To select this option, select the checkbox and enter the SMTP server
user name and password.
For security purposes, you must click
Save
and enter the admin user name and password to save
modifications or run commands. The default user name and password are both
admin
.
Reboot the card after any changes to these parameters (see the following section, “System Settings” on
page 39).
NOTE 1
If the host name is not used, the IP address supplied by the DHCP server must be
assigned through Static DHCP Assignment to maintain the connection with the
clients installed on the stations to be protected.
NOTE 2
During the first connection, if the DHCP query is not successful, the Network
Card-MS starts with the following IP configuration:
IP Address: 192.168.1.2
Subnet Mask: 255.255.255.0
Gateway Address: 0.0.0.0