![Eaton i-onEX Series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/eaton/i-onex-series/i-onex-series_administrators-and-user-manual_3865630068.webp)
4. Administration
i-on40 & i-onEX Range
Page 62
Walk test
The Walk Test menu allows you to test detectors without starting an alarm.
To “walk test” an alarm system you operate each detector in the system. If
the detector is working the control unit sounds a confirmation tone and
flags that the detector has passed the test. Simply walking past motion
detectors should be enough to trigger them, but you will have to open doors
and windows if you want to test any detectors attached to them.
Note that you
cannot
test wired HUA wired buttons, Fire detectors, and 24
hour zones during a walk test. The control unit will always start an alarm if
you activate those detectors. (A 24-hour zone has detectors that are
“live”
all the time, not just when you set the system.)
If you find a detector that does not work, call your installer.
To use the Walk Test menu:
1.
Make sure the display shows the
standby screen.
2.
Press .
3.
Key in your access code (or
present a tag).
4.
Press
until you see:.
5.
Press
.
The bottom line of the display
shows:
6.
Press
until you see:
7.
Press
.
The bottom line of the display
shows:
8.
Press
or
to turn a chime tone
on or off.
When the chime tone is on, the
keypads and loudspeakers will
sound a chime tone for each zone
that triggers while you are
performing the walk test.