13
Installation Guide: EV direct connect and junction box kits
EV DIRECT CONNECT AND JUNCTION BOX KITS
www.eaton.com
EV DIRECT CONNECT AND JUNCTION BOX KITS INSTALLATION
Connect EV smart breaker charger & EV connector
D
Conductors from the EV connector
are connected to the EV smart breaker
charger inside the approved junction
box via terminal blocks as described in
the following steps.
• Open the junction box cover and mount
the junction box to the wall .
• Remove the appropriate ¾-inch junction
box knockouts
(1)
to insert the EV smart
breaker charger conductors
(2)
and EV
connector cord
(3).
• Install the NM/SE connector
(4)
in the
knockout where the EV connector cord
will be inserted .
• Insert the EV connector cord through
the NM/SE connector in the knockout .
STEP D-1
EV direct c junction box kit
1
1
2
3
4
Supply line conductors
enclosed in conduit
per NEC and local
codes. All conductors
rated at highest
conductor rating.
Reference:
1.
NM/SE connector knockout
2.
EV smart breaker charger conductors
3.
EV connector cord
4.
NM/SE connector
Figure 4