List of Parameters – as delivered condition
The following tables show function, units and range of the parameters available in this controller.
Modifying the parameters is possible by using the keypad on the front of the card or by using the
ER9.3-Tool.
There are 4 different parameter types:
•
C-parameter C1.00 – C1.26: parameters to change the control behavior (Table 5)
•
E-parameter E00 – E20. parameters for extended setting (Table 6)
•
S-parameter S1.01 – S1.04 and S1.08: digital set values (Table 7)
•
R-parameter r1.01 –r1.04: ramp parameters (Table 8).
Column “Value” in Table 5 and Table 6 contains the recommended values for SP control by Eaton
Fluid Power GmbH. These values are chosen to establish stable working conditions.
Controller-Parameters
No.
Function
Unit
Step
Min
Max.
Code
Value
C1.00
Controller selection
---
1
0
4
0 = off
1 = P-PT1-I-DT1
2 =Remote
3 =dff
4 = dff
1
C1.01
Safety function
---
---
0
1
off = off; on = on
off
C1.02
Linearization
---
1
0
5
off = linear; 1 ... 5 =
curve
2
C1.03
Gain A
V/V
00.01
00.00
02.00
---
01.00
C1.04
Gain B
V/V
00.01
00.00
02.00
---
01.00
C1.05
Set value sign
---
---
- 1
+ 1
- 1 = negative
off = off
+ 1 = positive
Customer
C1.06
Set value offset
V
0.001
-9.999 +9.999
---
0.000
C1.07
Dead band compensation A
V
0.001
0.000
+9.999
0.000
C1.08
Dead band compensation B
V
0.001
0.000
+9.999
9.999 V = max.
current depending
on solenoid
selection
0.000
C1.09
Sensor type
Attention:
No negative controller output
possible when 10, 11 or 12 is
selected!
If E20 = 0 than type 1 to 12
available!
If E20 = 1 than only type 4 to 7
and 12 available!
---
1
1
12
1 = 0 ... 20 mA
2 = 4 ... 20 mA
3 = 12 mA
±
8 mA
4 = 0 ... 10 V
5 = 0 ...
±
10 V
6 = 6 V
±
2,5 V
7 = 7,5 V
±
2,5 V
8 = 6 V
±
5 V
9 = 7,5 V
±
5 V
10 = 0 ... 20 mA
11= 4 ... 20 mA
12 = 0 ... 10 V
6
C1.10
Actual value gain
V/V
00.01
00.00
04.00
---
1.8
C1.11
Actual value offset
V
0.001
-9.999 +9.999
---
0.000
C1.12
Actual value sign
---
---
- 1
+ 1
- 1 = negative
off = off
+ 1 = positive
1
C1.13
P-Portion KP1
V/V
00.01
00.00
04.00
---
02.00
C1.14
T-Portion for PT1 (to C1.16)
S
00.01
00.00
04.00
---
00.15
C1.15
Threshold (C1.13, C1.16)
V
0.001
0.000
+9.999
---
0.050
C1.16
P-Portion KP2
V/V
00.01
00.00
04.00
---
00.60
C1.17
I-Portion
V/s
00.01
00.00
04.00
---
0.000
C1.18
D-Portion
Vs
00.01
00.00
04.00
---
00.00