12
EATON
EP Control for Medium Duty 72400 Piston Pumps Parts & Service 08-10-0003-EN-0901 September 2001
Step 18
Carefully position the EP Control
electronic module. Tuck all cables
under the module.
Caution:
Avoid
pinching cables at mounting points.
Step 19
Install the four lockwashers and
four 10-24 button head cap screws.
Place two of the screws through
the “L” brackets. Using a 1/8” hex
key or bit socket, torque the four
screws to 60-68 lbf·in.
Step 17
Connect the four-pin connectors
between the EP Control electronic
module and the solenoid coils. The
connectors must be latched
securely.
Step 20
Power should still be disconnected
to the input device. Connect the
command input device to the three-
pin connector on the EP Control
electronic module.
Step 21
Connect the electrical power
source to the two-pin connector on
the EP Control electronic module.
Install a 3 Amp SLO-BLO
®
fuse per
the Interconnect Schematic on
page 12. Recheck your work and
then reconnect the power to the
vehicle or system.
Step 22
The pump is now ready to return to
operation.
Repair & Service