Disassembly
Step 2
Using a 5/32" hex wrench (or bit
socket), remove the two cap
screws on each side of the pump
holding the “L” brackets to the
pump.
Step 3
Using a 1/8" hex key (or bit socket),
remove the four 10-24 button head
cap screws and lockwashers on top
of the electronic control.
Disconnect the four-pin connector
between the EP Control module
and the solenoids. Caution must be
used when disconnecting these
connectors as they are latched with
keepers.
Step 1
Disconnect all power to the input
device. Carefully disconnect the
command input device from the
three-pin connector on the EP
Control electronics module by
releasing the connector latches.
Thoroughly clean the outside of the
EP Control and surrounding pump
surface.
To Pump
Repair & Service