background image

3

1   Introduction / Foreword

Installation and Operating Instructions  Web-Controller

   40071860236 (E)   February 2019   www.eaton.com

1   Introduction / Foreword

The  Web-Controller allows for comfortable and 

full control and monitoring for up to max. 800  

self-contained luminaires or modules. Many useful fea-

tures are implemented.
The luminaires are connected via a 2 core bipolar bus-

cable, subdivided on 4 or 2 lines (max. 200 luminaires on 

4 lines or 400 luminaires on 2 lines).
An integrated webserver allows an easy monitoring of all 

luminaires over an existing computer network, via a stan-

dard web browser, e.g. firefox. Thus a special software is 

not required and location independent monitoring is pos-

sible.
An optional PC-Software allows an comfotable 

configuration of the  Web-Controller via an USB-

cable connection.

The following features are available:

O

O

Housing for DIN rail mounting in a standard distribution 

cabinet

O

O

Up to 4 lines with max. 200 luminaires each, in total 

max. 800 luminaires

O

O

Íntegrated webserver for a comfortable monitoring via 

standard webbrowser

O

O

Integrated mail client for up to 10 recipients, mail 

events freely selectable

O

O

Blocking input with differential loop monitoring  

(1 kOhm)

Integrated e-mail function

@

Web-Controller: With 

integrated memory for storing the 

configuration and logbook

Visualisation of up to 800 luminaires 

(4 lines with max. 200 luminaires each 

or   

2 lines with max. 400 luminaires each, 

only with homogeneous installation of 

luminaires)

CGVision software: 

Configuration and full visualisa-

tion of 32 x 800 luminaires

Alternative:

Network PC or  Wireless 

Monitoring Set (optional): Access 

to the integrated web interface

USB stick: For convenient logbook 

analysis at the PC

Up to 32 controllers with 

800 luminaires each (only 

with homogeneous installa-

tion of luminaires)

      ...

Ability to store the con-

figuration and logbook via 

USB stick

Line 1

1

2

3

200

1

2

3

200

1

2

3

200

1

2

3

200

Line 2

Line 3

Line 4

IP connectivity

O

O

Two free programmable digital inputs

O

O

Two free programmable relay outputs (changeover con-

tacts)

O

O

Automatic luminaire search function (no manual 

addressing required)

O

O

Automatic function / duration test of all luminaires, 

assigned into 8 test groups

O

O

Luminaires with maintained light can be switched off, 

free selectable (in non-maintained light)

O

O

2 x USB ports,1 x for Backup via USB-stick, 1 x for easy 

configuration via PC-software

O

O

Intergrated building layout programming with max. 30 

layouts (external software as option)

O

O

Downloadable logbooks

O

O

CGVision fully configuration and monitoring software 

for max. 32  Web-Controller available (as 

option)

 IMPORTANT 

The  Web-Controller is compatible with the older 

CGLine self-contained system. If one or more CGLine 

luminaire is connected, the controller switches automti-

cally to CGLine compatibility modus. Some fea-

tures are not available then.

 NOTE 

For setting up the Adaptive Evacuation mode, please read 

the AE manual.

Fig . 1 .  Application example

Содержание CGLine+ Web Controller

Страница 1: ...Installation and Operating Instructions CGLine Web Controller Target group Electrical specialists CGLine Web Controller...

Страница 2: ...EENS 13 7 1 Home start screen 13 7 2 Start screen after registration 14 7 3 Overview of all faulty luminaires complete overview 15 7 4 Overview of all faulty luminaires for each zone 16 7 5 Overview o...

Страница 3: ...each or 2 lines with max 400 luminaires each only with homogeneous installation of CGLine luminaires CGVision software Configuration and full visualisa tion of 32 x 800 luminaires Alternative Network...

Страница 4: ...s policies O O Restrict Network Access Ideally CGLine Web Controller should be installed on a segregated net work However when the CGLine Web Controller is connected to a wider network make sure that...

Страница 5: ...hnical regulations when set ting up and operating electrical operating equipment 5 1 Assembly Observe impermissible temperatures at the installation location during mounting The permissible ambient te...

Страница 6: ...tional method O O Press the service pin 1 sec but 3 sec function test started for all luminaires O O Press the service pin 6 sec only new luminaires search started 1 6 7 8 9 10 2 3 4 5 3 Push buttons...

Страница 7: ...Cable length line Cross section Length Total lines 0 5 qmm 260 m 660 m 1 0 qmm 520 m 1320 m 1 5 qmm 800 m 2000 m Table 4 Electrical data line Power supply bus 25 V Max permissible voltage drop 6 V Bus...

Страница 8: ...ction enables connection of the CGLine Web Controller to a standard PC Controller functions can be programmed via the PC and a configuration software e g luminaire configurations The PC configuration...

Страница 9: ...llowing screen is displayed 1 2 The following screen is displayed Mark the entry Internet protocol version 4 1 then con tinue with Properties 2 Usually the network card is on DHCP i e Automatically re...

Страница 10: ...to the address bar The start screen of the CGLine Web Controller opens The screen shows an overview of the installed CGLine system with sum status information To have access to the submenus a login 1...

Страница 11: ...ar In the submenu configura tion 1 It is possible to change the network set tings 1 6 5 Modifying of the language date and time To change the language to English please click on Configuration 1 in the...

Страница 12: ...via the names is pos sible The CGLine Web Controller is supplied with a factory set static IP address of 192 168 1 200 3 Operation via DHCP is possible but in this case it is recommended to select st...

Страница 13: ...Password GUEST 1 The Admin Account allows full access to the CGLine Web Controller e g start function test The User account allows only access for monitoring the status of the controller and connecte...

Страница 14: ...Yellow min 1 lumi naire faulty O O Red min 3 luminaires faulty e g lamp failure After the login the navigation menu appears on the left side 1 O O Home The start screen is accessed via Home at any tim...

Страница 15: ...le to enter to the building layout picture if it is prepared The menu Oveview 1 and the tab Overview luminaire failure 2 display all lumi naires with a fault 3 O O L line no 1 4 O O Z zone 2 16 O O B...

Страница 16: ...r 40071860236 E February 2019 www eaton com 7 4 Overview of all faulty luminaires for each zone All luminaires with a fault in a zone are displayed in the Overview menu 1 and the Zone tab 2 Via the dr...

Страница 17: ...erview luminaires 2 shows all installed luminaires on the CGLine Web Controller 1 2 7 6 Information information text of the luminaires This screen shows the name with max 20 char acters and informatio...

Страница 18: ...of luminaires addresses For changing the configuration of luminaires addresses please follow the steps below 1 Click on the tab Luminaires The table with all the lumi naires installed appears 2 Click...

Страница 19: ...uration tests are aborted O O Switch maintained mode ON OFF Luminaires in maintained mode L applied can be switched ON or OFF if luminaire supports this function O O Update luminaire status Actualisia...

Страница 20: ...s On the Test tab 2 in the configuration menu 1 it is possible to deter mine start times for a function test and duration test for up to 8 groups It is also possible to set a test interval via which t...

Страница 21: ...d mode luminaires of the line as long as the input is active O O Start function test With positive pulse starts the function test with all luminaires O O Stop FT DT Interrupts a duration test or funct...

Страница 22: ...necessary after the commissioning to correctly set the date and time in the CGLine Web Controller here 5 2 1 4 5 3 7 13 Network settings Follwing settings are possible O O DHCP Dynamic Host Control Pr...

Страница 23: ...plete logbook is downloadable via log book dat This file is only usable with the CGLine PC software see manual CGLine PC software The CGLine Web Controller contains an integrated e mail client 1 that...

Страница 24: ...n layouts of the building or areas It is pos sible to import up to 30 building layout plans with max 200 luminaires each The colour of the luminaire shows the status e g red luminaire failure To use t...

Страница 25: ...ing layouts can displayed now by the folder List of building layouts 1 With click on the name of the layout which is displayed as hyperlink with xml exten sion 2 the layout can load from the controlle...

Страница 26: ...n there is a search function 1 2 This enables quickly finding any defective luminaires in a building To find a luminaire in the layout plan the line the zone and the luminaire to address can be select...

Страница 27: ...entered here After confirming via Add the devices are automati cally created A device can be deleted from the list again via Delete 3 3 1 2 7 24 Overview all Web Controller With several installed CGLi...

Страница 28: ...ht solution for the application But decision makers demand more than just innovative pro ducts They turn to Eaton for an unwavering commitment to personal support that makes customer success a top pri...

Отзывы: