3. Installation
3.5 Preparing the device for operation
3.5.2 Power supply via plug connector
CAUTION
Arrange for an electrician to install the power supply for the plug
connectors.
The required connector for the device is included as standard.
Plug connector
need for
MSTBT 2.5/3-ST-5.08
Panel-PC , Terminal and Terminal with Extender RX
MSTBT 2.5/3-ST-5.08
Box-PC with functional earth
MSTBT 2.5/4-ST-5.08
XP-504-EXT module
Connect the individual conductors.
7 mm
(0.28”)
Terminal capacity
in mm²
solid
0.75 to 2.5
AWG19-AWG14
Use the plug to terminate the connection cable for the power supply in advance.
Plug the pre-assembled plug into the socket on the enclosure.
Pay attention to the polarity "+24V" and "0V".
Connect the power supply cable to a 24 VDC power supply that meets the requi-
rements for safety extra-low voltages (SELV) set forth in IEC/UL 61010-2-201.
Specifications connection 24 VDC power supply
Copper conductor
Use copper wire only, designed for a temperature of at least 65 °C
Cross-section
at least 0.75 mm
2
/ max. 2.5 mm
2
(drain wire or conductor)
min. AWG19 / max. AWG14
Tightening torque
0.5 - 0.6 Nm (4.4 -5.3 lb-in)
for the screws on the respective plug connector
Strip length
7 mm
Tab. 10: Specifications for connection to 24 VDC power supply
XP-504
04/2022 MN048028EN Eaton.com
63
Содержание 199996
Страница 1: ...Manual 04 2022 MN048028EN XP 504 Manual...
Страница 4: ......
Страница 82: ...4 Using peripheral devices External connections 4 7 DVI I 82 XP 504 04 2022 MN048028EN Eaton com...
Страница 86: ...5 Commissioning 5 2 Running the XP 504 86 XP 504 04 2022 MN048028EN Eaton com...
Страница 98: ...7 Operating System 7 2 Windows 10 Enterprise LTSC 98 XP 504 04 2022 MN048028EN Eaton com...
Страница 100: ...8 Faults 100 XP 504 04 2022 MN048028EN Eaton com...
Страница 130: ...Appendix A 2 Further usage information 130 XP 504 04 2022 MN048028EN Eaton com...