GT200 series general purpose inverter instruction manual
F9.44
Stage 15
setting
LED units digit
:
0
:
Multistage frequency
4(F9.29)
1
:
Determined by F1.02
function code
2
:
Multistage closed loop given
4(F8.34)
3
:
Determined by F8.01
function code
LED tens digit
:
0
:
Foreward
1
:
Reversal
2
:
Determined by run command
LED hundreds digit
:
0
:
Acceleration and
deceleration time 1
1
:
Acceleration and
deceleration time 2
2
:
Acceleration and
deceleration time 3
3
:
Acceleration and
deceleration time 4
1
000
○
F9.45
Stage 15
running time
0.0
~
6500.0s
0.1
0.0
○
Protection function parameter FA group
FA.00
Motor overload
protection
mode selection
0
:
No action
1
:
Common motor (with low speed
reimbursement)
2
:
Variable frequency motor
(without low speed reimbursement)
1
1
×
FA.01
Motor overload
protection
coefficient
20.0
~
110.0%
0.1%
100.0%
×
FA.02
Motor
over-temperatu
re protection
threshold
0
℃
~200
℃
1
110
*
FA.03
Motor
over-temperatu
re warning
threshold
0
℃
~200
℃
1
90
*
63