GT200 series general purpose inverter instruction manual
Chapter 3 Frequency Inverter’s operation and
instruction
3.1button function description
The frequency converter operation panel is provided with 8 keys, each function
definition of the key is shown in table3-1.
Table 3-1 operation panel function table
Keys
Name
Icon
Function explanation
PRG
Edit/Exit
Key
PRG
Entry or exit programming status
Shift/moni
tor key
In the edit state, you can choose to set the data
modification bit; in other state, switch display
monitoring parameters
ENT
Confirm
key
ENT
Enter menu or data confirmation
Rotating
encoder
M-F
Multi-fun
ctional
key
M-F
According to F0.01 set effective, ex factory
value: point action control
RUN
Operation
key
RUN
In the operation keyboard mode, the button
inverter operation
STOP
RESET
Stop/ reset
key
STOP/RESET
When the frequency inverter is in the normal
operation condition, if the frequency innverter
operates the instruction channel to set the
keyboard to stop the effective way, presses this
key frequency change to stop according to the set
way. When the inverter is in fault state, press the
key to reset the inverter and return to normal
shutdown state.
QUICK
Shortcut
key
QUICK
Switch to different menu mode according to
F0.05 value
Tip: keys RUN, M-F, STOP/RESET characteristics are also restricted by the function
code FC.31.