GT200 series general purpose inverter instruction manual
9.16
Stage 5 setting
LED units digit
:
0
:
Multistage frequency
4(F9.04)
1
:
Determined by F1.02
function code
2
:
Multistage closed loop given
4(F8.23)
3
:
Determined by F8.01
function code
LED tens digit
:
0
:
Foreward
1
:
Reversal
2
:
Determined by run command
LED hundreds digit
:
0
:
Acceleration and
deceleration time 1
1
:
Acceleration and
deceleration time 2
2
:
Acceleration and
deceleration time 3
3
:
Acceleration and
deceleration time 4
1
000
○
F9.17
Stage 5
running time
0.0
~
6500.0s
0.1
20.0
○
F9.18
Stage 6 setting
LED units digit
:
0
:
Multistage frequency
4(F9.04)
1
:
Determined by F1.02
function code
2
:
Multistage closed loop given
4(F8.23)
3
:
Determined by F8.01
function code
LED tens digit
:
0
:
Foreward
1
:
Reversal
2
:
Determined by run command
LED hundreds digit
:
0
:
Acceleration and
deceleration time 1
1
:
Acceleration and
deceleration time 2
2
:
Acceleration and
deceleration time 3
3
:
Acceleration and
deceleration time 4
1
000
○
56