![EasyDrive Electric GT200-2S0007G Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/easydrive-electric/gt200-2s0007g/gt200-2s0007g_user-manual_523328047.webp)
GT200 series general purpose inverter instruction manual
F7.07
Over current
stall action
selection
0
:
Constant speed ineffective
1
:
Constant speed effective
Note
:
Acceleration and deceleration
is always effective
1
1
×
F7.08
Over current
stall gain Kp
0~100
1
6
×
F7.09
Over current
stall integral
time
1~1000
1
100
×
F7.10
Rotational
speed tracking
gain KP
0~100
1
10
×
F7.11
rotational
speed tracking
integral time
1~1000
1
50
×
F7.12
Rotational
speed tracking
acceleration
0.1~60.0S
0.1s
6.0s
F7.13
Rotational
speed tracking
judging
threshold
1~100%
1%
10%
F7.14
Instantaneous
stop/no stop
function
selection
0
:
No action
1
:
decelerated
2
:
Ramp to stop
1
0
×
PID control parameter F8 group
F8.00
Closed loop
running control
selection
0
:
No action
1
:
Action
1
0
×
F8.01
Given channel
selection
0
:
Number given;
(
Refer to F8.06 when F8.02=6;
refer to F8.05 in other conditions
)
1
:
AI1
;
2
:
AI2
;
3
:
AI3(Expansion card)
Note
:
For speed closed loop, analog
given 10V for synchronous speed of
maximum frequency F1.06
1
1
○
47