Troubleshooting 41
Problem
Solution
No heat
1. Is the display on the temperature controller on? If
not, check for 220 Volts on terminals 9 and 10. If
there is voltage, replace the temperature
controller.
2. If the display is on and SV is set higher than PV, is
there a red light on? If not, replace the
thermocouple.
3. If there is a red light on, check for 220 VAC from
any wire number 8 to terminal 13, and then
terminal 14. If no voltage, replace the temperature
controller.
4. If there is 220 VAC, check for 220 VAC on coil of
heater contactor. If there is voltage and the
contactor is not pulling in, replace contactor.
5. If there is no 220 VAC, check heater bank on / off
switch. The best way to check this is to disconnect
the wires and check resistances (Ohms).
Delay cool-down does not
work
Adjust temperature controller TT1 using the menus,
Menu #1 and Menu #2, that follow. Refer to
adjustment procedure to adjust the Delay Cool-Down
setting.
Temperature Controller Default Settings
Menu 1
Temperature Controller 1
In-t
-
JIC.H
Eu-1
-
AL-4
Eu-2
-
AL-5
AL-T
-
AL-B
AT.T
-
TUN1
PIDT
-
PID.F
O-FT
-
HEAT
Unit
-
°F
H-SC -
450°
L-SC
-
32
Ramp -
OFF
LOC
-
ON
Temperature Controller 2
In-t
-
JIC.H
(same as 1)
Eu-1
-
AL-0
Eu-2
-
AL-5
AL-T
-
AL-B
(same as 1)
AT.T
-
TUN1 (same as 1)
PIDT
-
PID.F (same as 1)
O-FT
-
HEAT (same as 1)
Unit
-
°F
(same as 1)
H-SC -
450°
(same as 1)
L-SC
-
32
(same as 1)
Ramp -
OFF
(same as 1)
LOC
-
ON
(same as 1)
Содержание ET2008
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 43: ...Parts List 43 Parts List Electrical Eastey Bundling Shrink Tunnel Part No Description...
Страница 44: ...44 Parts List Part No Description...
Страница 45: ...Parts List 45 Mechanical Hood Parts Part No Description...
Страница 46: ...46 Parts List Conveyor Parts Part No Description...
Страница 47: ...Parts List 47 Part No Description...
Страница 48: ...48 Parts List...
Страница 53: ...Appendix A Electrical Schematic 53...
Страница 57: ......