Introduction 11
Explanation of Model Numbers
•
E = Manufactured by Eastey Enterprises Inc., division of Engage Technologies.
•
T = Tunnel; machine is a Professional Series Shrink Tunnel.
•
_ _ = 20, 24, 36, 48, 56, or 70 — First two digits indicate the nominal chamber
width or width of the conveyor belt in inches: 20, 24, 36, 48, 56, or 70 inch
conveyor widths are available. (Chamber width will typically be approximately
equal to the width of the conveyor.)
•
_ _ = 08, 12, 16, or 20 — Remaining two digits indicate height of the bundling
chamber in inches: 8 inch, 12 inch, 16 inch, or 20 inch chamber height.
•
_ _ = MB, LR, DR, or PB — Indicates the conveyor type. MB indicates a stainless
steel mesh belt, standard. LR indicates Live Roller
•
V _ = V1, V2, or V6 — Indicate the Voltage and Phase required for input power.
V2 = 220V, three-phase is the standard voltage; 220V, single-phase and 480V,
three-phase phase are options available on some models.
•
Additional letters and numbers after the voltage and phase indicate additional
information if required.
Example
:
- Model number ET3620-MBV2-nnnn: ET indicates that it is an Eastey Shrink
Tunnel. 3620 indicates the conveyor width is 36 inches (chamber width is
approximately the same) and chamber height is 20 inches. MB indicates that the
conveyor uses stainless steel mesh belt, and V2 indicates 220 volts and three
phase. If SP appears in the model number suffix, this indicates it is a custom
model (special project) and the numbers following SP (final numbers of the
model number) indicate the project number.
Standard features
•
Designed to shrink-seal most polyolefin, polyethylene, and PVC shrink films
•
All-welded main frame from 12-gauge steel
•
Live roller, “dead” roller, or stainless steel mesh belt conveyor standard; optional
plastic belt conveyor
•
Sealed bearings (not bushings) on drive and idler shafts
•
Adjustable digital solid-state temperature control for a variety of films
•
Four-directional air-flow provides positive shrinking
•
Variable air-flow and air velocity for a variety of products and applications
•
Bottom air flow adjustment — full on, half on, or full off
•
Large ducting creates more air volume inside tunnel
Содержание ET2008
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 43: ...Parts List 43 Parts List Electrical Eastey Bundling Shrink Tunnel Part No Description...
Страница 44: ...44 Parts List Part No Description...
Страница 45: ...Parts List 45 Mechanical Hood Parts Part No Description...
Страница 46: ...46 Parts List Conveyor Parts Part No Description...
Страница 47: ...Parts List 47 Part No Description...
Страница 48: ...48 Parts List...
Страница 53: ...Appendix A Electrical Schematic 53...
Страница 57: ......