32 Adjustments
Over Temperature Alarm Setting (L-Sealer)
1. Press and hold the MD button for approximately three (3) seconds.
IN-T is displayed.
2. Press and hold the MD button and up-arrow ( ) buttons at the same time for
three (3) seconds to activate the menu. Scroll to LOC and press the left-arrow ( )
button. On will begin flashing. Press the down-arrow button ( ). On will turn to Off
and press the MD button until LOC appears, indicating that the Off setting is
locked.
3. Press the MD button until EU-1 appears (Event 1). Below EU-1, AL-6 should
appear. If not, use the up and down buttons to select AL-6.
4. Now return to LOC and change it to On.
5. Press and hold both the MD and up-arrow ( ) buttons at the same time for three
(3) seconds to access the other menu.
6. Scroll through the menu using just the MD button and turn LOC Off.
7. Scroll through the menu until AL-1 appears. This is your high alarm. The normal
factory setting is 500°.
8. Return to LOC and change it to On.
PV
SV2
AT
OUT
EV1
EV2
SV
MD
AT