Eagle Eye SG-1000C User Manual 

 

 

 

13 

 

7. Explanation of Error Messages 
 

The SG-1000 will indicate an error message when there is a problem with the operation 
on the instrument. Error messages that may be displayed are explained below. 
 

“AAA” Zero-setting error 

 

Zero-setting was performed 
without water in the Sample 
Chamber.

 

 

Zero-setting was performed with 
a sample other than water in the 
Sample Chamber.

 

 

Note: This error message may not occur 
when the concentration of the sample is 
low (close to that of water). Be sure 
distilled or tap water is used when 
performing zero-set.  
 

“LLL” Sampling error 

 

Electrolyte in the Sample 
Chamber is insufficient to cover 
the prism surface or air bubbles 
may be present.  

 

“HHH” Range-over error 

 

The sample measured is out of 
range of the SG-1000. 

 
 
 
 
 
 
 

“HHH” Battery error 

 

This error message is displayed 
after zero-setting and 
measurement when the battery is 
low. Replace the battery with a 
new one.  

 

The SG-1000 may operate in an 
abnormal manner without 
displaying the “HHH” when the 
battery is low. Replace the battery 
when abnormal operation is 
noticed.  

 

“. . .” Temperature Error 

 

The temperature of the 
sample in the Sample 
Chamber is below 14 degrees 
F or above 122 degrees F. 

 

 

This error will also appear 
after zero-setting if the 
temperature is out of range. 

 

 
 
 
 
 

8. Temperature Display 

 

Содержание SG-1000

Страница 1: ...SG 1000 Specific Gravity Tester User Manual The BEST Battery Testing Equipment The BEST Customer Support PERIOD www eepowersolutions com Copyright 2012 Eagle Eye Power Solutions LLC V1 0...

Страница 2: ......

Страница 3: ...shed onto the skin or clothing rinse with sufficient amounts of cold water If it gets into an eye flush with cold clean water for about 15 minutes and seek immediate medical attention Remove the batte...

Страница 4: ...mes and Functions of Parts 4 2 Inserting the Nozzle 6 3 Inserting the Battery 7 4 Attaching the Wrist Strap 8 5 Zero Setting 9 6 Measurement of Sample 11 7 Explanation of Error Messages 13 8 Temperatu...

Страница 5: ...Eagle Eye SG 1000C User Manual 4 1 Names and Functions of Parts...

Страница 6: ...setting 4 START OFF key Press to take measurement To turn off the instrument press and hold down the key for 2 seconds 5 Battery Cover Remove to replace battery 6 Nozzle Cap Used to protect tip of noz...

Страница 7: ...e is packed separately from the Main unit Insert the Nozzle to Main Unit following the procedure described below 1 Push the Nozzle into the hole located 2 Then fit the nozzle into the slit by at the b...

Страница 8: ...itself is not guaranteed and be sure to use a new battery if its voltage is low 3 Close the Battery Cover and using a Screwdriver turn the locking pin to the CLOSE position Note The SG 1000 does not h...

Страница 9: ...SG 1000C User Manual 8 4 Attaching the Wrist Strap Attach the wrist strap to the hook located on the lower side of the Main Unit When measuring samples loop the strap around your wrist to avoid any a...

Страница 10: ...at the Sample Chamber has been filled with water If bubbles are present in the Sample Chamber operate the Tube Pump again to refill water into the Sample Chamber 2 Dip the tip of the Nozzle in water a...

Страница 11: ...Chamber Allow the unit to equilibrate to the ambient temperature before taking measurements Zero setting can be performed anytime Using water the unit will be calibrated to zero Use distilled water fo...

Страница 12: ...d squeeze and release the Tube Pump a few times to draw the sample into the sample chamber Once the sample is drawn into the unit Drain it completely and then refill the sample into the unit again Thi...

Страница 13: ...er for a few days the prism surface will be soiled and consequently cause errors during measurement To clean the prism surface use a soft tissue soaked with ethyl or isopropyl alcohol If the electroly...

Страница 14: ...when performing zero set LLL Sampling error Electrolyte in the Sample Chamber is insufficient to cover the prism surface or air bubbles may be present HHH Range over error The sample measured is out o...

Страница 15: ...ce 1 To replace the Tube Pump slide it to the left to release and replace it with a new one 2 After measurement fill and drain the Sample Chamber with distilled or tap water several times to clean Com...

Страница 16: ...The Sample Chamber Sample Hook and or Tube Pump may have been freed from the normal position Make sure the Sample Chamber Hook is properly attached to the unit Adjust the Sample Chamber and Tube Pump...

Страница 17: ...Eagle Eye SG 1000C User Manual 16...

Страница 18: ...the ambient temperature and the sample temperature close to equilibrium Does the battery need replacement Is the O ring damaged in the Sample Chamber Is the Tube Pump damaged Is the Nozzle damaged Is...

Страница 19: ...ttery Refer to page 8 on how to replace the battery and other remarks The unit uses a 9V DC battery 006P Is the O ring damaged in the Sample Chamber Remove the Sample Chamber cover from the unit see p...

Страница 20: ...the Nozzle is securely attached Leakage of liquid or air can be observed if the Tube Pump Nozzle or cover has been damaged or the Nozzle is loose If damage is found replace the damaged part Two spare...

Страница 21: ...he sample before pressing the START key 11 Specifications Model SG 1000 Detection method Optical refraction Measurement range Specific gravity of electrolyte 1 000 to 1 300 Resolution 0 001 Measuremen...

Отзывы: