Description
2-21
1
2
3
4
5
2.3.4.3
1 "ALARM" loop female connector,
• Wire section: 0.25 - 0.50 mm
2
max (AWG 20-24)
• Insulating diameter: 1.60 - 2.0 mm
• Alarm loop status:
- closed loop: no alarm
- open loop: alarm
The alarm loop state is active (open loop) if one of the following alarms is present:
• SWR alarm
• LNA alarm,
• CARRIER alarm (transmimssion carrier),
• Fan 1 alarm,
• Fan 2 alarm,
• Synchronisation board pilot alarm,
• Synchronisation board PWR alarm,
• IDR IDO 3G internal temperature alarm,
• Convertor PWR alarm,
• Convertor fan alarm.
2.3.5
Environmental specifications
Operating:
• dry heat
: standard IEC 60068-2-2
+ 55
°
C permanent transmission at 15 W,
30 % RH without solar radiation
(65
°
C, 2 W)
• cold
: standard IEC 60068-2-1
- 10
°
C
• mechanical resistance: class 3M1
Storage / transport
• dry heat
: standard IEC 60068-2
+ 70
°
C, 30 % HR
• cold
: standard IEC 60068-1
- 25
°
C
• humid heat
: standard IEC 60068-56
+ 25
°
C, 98 % HR
+ 55
°
C, 90 % HR
Содержание CASSIDIAN IDR IDO 3G
Страница 5: ...DEFENDING WORLD SECURITY IDR IDO 3G Technical Manual TMO PS11209BENAB01 07 2012...
Страница 150: ...IDR IDO 3G_MC9_IDR IDO_FAV_PRES_01_01 3 1 2 4 5 7 6 8 9 10 11 15 14 13 12 18 17 16 Plate 6 II IDR IDO 3G FRONT PANEL...
Страница 152: ...1 7 2 3 4 5 IDR IDO 3G_MC9_IDR IDO_3 4 AR OUVERT_PRES_01_01 6 Plate 6 III IDR IDO 3G INTERNAL VIEW...
Страница 154: ...1 2 3 4 5 6 7 8 9 10 11 RIP IDO 3G_MC2_LED_ALIMENTATION_FAV_01_01 Plate 6 IV IDR IDO 3G PRIMARY MAINS OR DC CONVERTERS...
Страница 163: ......
Страница 164: ...MC2 RR APP 00033 02 02 EN...