![Eads CASSIDIAN IDR IDO 3G Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/eads/cassidian-idr-ido-3g/cassidian-idr-ido-3g_technical-manual_3260847130.webp)
Maintenance
This d
t and its contents are the property of CASSIDIAN
nd must not be copied or circul
7
1
2
3
4
5
REPLACING THE RF POWER DIVIDER
REMOVAL
• Disconnect the 3 cables connected to the RF power divider (see Plate 6.VIII).
• Unscrew the 2 captive screws holding the RF power divider (see Plate 6.III, item 7).
• Remove the RF power divider (item 7).
INSTALLATION
• Check that the functional technical state of the new RF power divider is compatible with
the old one (see Section 1.3, Document [3]).
• Install the new RF power divider (item 7).
• Lock the 2 RF power divider screws on the chassis.
COMPLEMENTARY OPERATION(S)
• Replace the upper cover (see Plate 6.I, item 1).
• Test the IDR IDO 3G (see Sheet P-2).
SHEET E-4