![Eads CASSIDIAN IDR IDO 3G Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/eads/cassidian-idr-ido-3g/cassidian-idr-ido-3g_technical-manual_3260847107.webp)
Maintenance
4-31
7
1
2
3
4
5
SHEET
SYMPTOM(S)
PROBABLE CAUSE(S)
CORRECTIVE ACTION
• red "RX DEF"
• Reception chain at fault
(LNA function).
• Power up/down the IDR IDO 3G using the
primary converter's "I/O" switch
(Plate 6.IV, item 2 or 9) (wait until the
power supply stops before putting the
switch back to "I").
• If the fault persists, contact the
manufacturer's customer support service.
Duplexer LED:
• "PWR" off
• Duplexer power supply at
fault.
• Check that the primary converter's “I/O”
switch (Plate 6.IV item 2 or 9) is set to “I”.
• Power up/down the IDR IDO 3G using the
primary converter's "I/O" switch
(Plate 6.IV, item 2 or 9) (wait until the
power supply stops before putting the
switch back to "I").
• If the fault persists, contact the
manufacturer's customer support service.
• "TX" off
• Duplexer cable (“TX”) -
3G PA-TRX module (“RF”)
incorrectly connected or
3G PA-TRX module at fault.
• Transmission state positioned
to
[Off]
.
• 3G PA-TRX module switch set
to "O".
• Programming fault on a
channel or duplexer channel
out of band.
• Connect the cable correctly.
• Check that the 3G PA-TRX module's “I/O”
switch (Figure 2.1, item 14) is set to “I”.
• Check on the control and configuration PC
that the transmission state is set to
[On]
(state bar in the bottom of the screen). If
necessary, enable transmission
(see
Section 3.4.4.
)
• If the fault persists, power down the
IDR IDO 3G using the primary converter's
"I/O" switch (Plate 6.IV, item 2 or 9) (wait
until the power supply stops before putting
the switch back to "I").
• If the fault persists, contact the
manufacturer's customer support service.
FAULTS INDICATED BY LEDS (3/4)
Содержание CASSIDIAN IDR IDO 3G
Страница 5: ...DEFENDING WORLD SECURITY IDR IDO 3G Technical Manual TMO PS11209BENAB01 07 2012...
Страница 150: ...IDR IDO 3G_MC9_IDR IDO_FAV_PRES_01_01 3 1 2 4 5 7 6 8 9 10 11 15 14 13 12 18 17 16 Plate 6 II IDR IDO 3G FRONT PANEL...
Страница 152: ...1 7 2 3 4 5 IDR IDO 3G_MC9_IDR IDO_3 4 AR OUVERT_PRES_01_01 6 Plate 6 III IDR IDO 3G INTERNAL VIEW...
Страница 154: ...1 2 3 4 5 6 7 8 9 10 11 RIP IDO 3G_MC2_LED_ALIMENTATION_FAV_01_01 Plate 6 IV IDR IDO 3G PRIMARY MAINS OR DC CONVERTERS...
Страница 163: ......
Страница 164: ...MC2 RR APP 00033 02 02 EN...