Maintenance
This d
t and its contents are the property of CASSIDIAN
nd must not be copied or circul
7
1
2
3
4
5
REMOVAL
• Loosen the captive screw on the convertor (see Plate 6.III, item 2).
• Remove the converter.
INSTALLATION
• Check that the functional technical status of the new converter is compatible with the old
one (see Section 1.3, Document [3]).
• Slide the new convertor into its housing on the front panel.
• Tighten the holding screw.
COMPLEMENTARY OPERATION(S)
• Connect the cable on the front panel (see Plate 6.VII item 7 or 8 and 9).
• Set the “I/O” switch (see Plate 6.IV, item 2 or 9) on the convertor (item1 or 6) to “O”.
• Test the IDR IDO 3G (see Sheet P-2).
SHEET E-8
CAUTION: Risk of burns when handling the converter. If necessary, wait for it
to cool down.