ELiiXA® UC8/UC4
51
Eliixa_Color–revF 04/11
e2v semiconductors SAS 2011
⇒
Read function : “
r ffcg
<addr> <nbrval> [crcreq]
” : Read
<nbrval>
FPN user coefficients
starting from
<addr>
address. If
[crcreq]
is equal to 1, the crc will be calculated on the
outputted value.
<nbrval>
is between 1 and 10
<addr>
starts from
•
1 for Red coefficients
•
5001 for Blue Coefficients
•
10001 for Green coefficients
•
15001 for NIR Coefficients
Output is:
<val> …[crcval]
⇒
Write function :”
w ffcg
<addr> <nbrval> <val> … [crcval]
” : Write
<nbrval>
FPN user
coefficients starting from the
<addr>
address. If
[crcval]
is added, the crc value is computed
on the all the
<val>. <val>
is signed.
<addr>
starts from
•
1 for Red coefficients
•
5001 for Blue Coefficients
•
10001 for Green coefficients
•
15001 for NIR Coefficients
<nbrval>
is between 1 and 10
<val>
is between
0 and 16383
•
FFC User Bank Management
:
The new-processed FFC can be saved in 4 x User banks (both Gains and
Offsets in the same time).
Ö
Read function
“
r rffc
” : Get the current Tap Bank used (0: Factory or 1 to 4)
“
w rffc
<val>
” : Load Tap Bank from bank <val> (0: Factory or 1 to 4)
Ö
Write function :
“
w rffc
<val>
” : Save the current Tap Balance in the User bank <val> (1 to 4)