ELiiXA® UC8/UC4
31
Eliixa_Color–revF 04/11
e2v semiconductors SAS 2011
•
Exposure time
:
Defines the integration time when set in the Camera
.
This command is available in the
CommCam “Exposure” section :
Ö
Read function : “
r tint
”;
Return by the camera : Integer from 1 to 65535 (=0,1µs to 6,5535ms)
Ö
Write function : “
w tint
” <value> ;
This value of integration time is taken in account only when the synchronisation mode is “free run” (0) or
“Ext Trig with Integration time set” (1). Otherwise it’s ignored.
•
Line Period
:
Defines the Line Period of the Camera in Timed mode
.
This command is available in the
CommCam “Exposure” section :
Ö
Read function : “
r tper
”;
Return by the camera : Integer from 1 to 65535 (=0,1µs to 6,5535ms)
Ö
Write function : “
w tper
” <value> ;
The line period is active only in Free Run mode. It’s also disabled if in this mode, the Integration time is
set higher than the Line Period.
The Line frequency indication (line per second) is calculated as : 1/Line Period.